B-233 Haemoglobin Variants and Their Impact on HbA1c Measurement: Experience with Two Routine Methods

Oct 2026 · Clinical Chemistry · 0 citations

TL;DR

Comparing HbA1c results obtained by PEIT with those from HPLC to evaluate agreement and potential clinical interchangeability in patients with common haemoglobin variants shows acceptable agreement without evidence of substantial systematic or proportional error.

Abstract

Haemoglobin A1c (HbA1c) measurement is central to the diagnosis and monitoring of long-term glycemic control in people with diabetes mellitus. High-performance liquid chromatography (HPLC) is widely regarded as the gold standard method, whereas particle-enhanced immunoturbidimetry (PEIT) offers operational simplicity and faster turnaround. The accuracy of HbA1c methods can be affected adversely by the presence of haemoglobin (Hb) variants. This study compared HbA1c results obtained by PEIT with those from HPLC to evaluate agreement and potential clinical interchangeability in patients with common haemoglobin variants. Paired HbA1c values from sixty-seven patients were analysed using HPLC and PEIT. Among the 67 samples analysed, Hb variants were distributed as HbD (n=26), HbE (n=28), increased HbF (n=5), HbS (n=4), increased HbA2 (n=2), and HbC (n=2). Data analysis was undertaken for the entire cohort of 67 samples, as well as separately for the subgroups carrying HbD and HbE variants. Agreement was assessed using Bland–Altman analysis and Passing–Bablok regression. In the entire cohort of 67 samples, Bland–Altman analysis revealed a mean bias of –1.08%, indicating that the test method tends to underestimate HbA1c levels. The 95% limits of agreement suggested that, in individual cases, results may vary by approximately ±3% relative to the reference method. Passing–Bablok regression yielded the equation y = –0.9 + 1.0x, with a slope of 1.0 and an intercept of –0.9. The slope being close to unity indicates good proportional agreement between the two methods. The negative intercept suggests a small constant bias, which is not statistically significant. Overall, the two methods demonstrate acceptable agreement without evidence of substantial systematic or proportional error. A strong correlation was observed between the two methods (r = 0.86, p < 0.0001). In the subgroup HbD variant, Passing-Bablok regression yielded the equation y = –1.187 + 1.07x. The slope being slightly above 1 suggested a tendency toward proportional overestimation by the test method; however, the wide confidence interval (0.596–1.50) indicates substantial uncertainty. The negative intercept suggested a slight constant underestimation. Bland–Altman analysis showed a mean bias of –1.16%, indicating that the test method consistently underestimates HbA1c. The 95% limits of agreement suggested that, for individual patients, results may differ by as much as ±3–3.5% from the reference method. In the subgroup of HbE variant, Bland-Altman analysis revealed a mean bias of –1.06%. The 95% limits of agreement showed that individual measurements may vary by up to nearly –3% on the lower side and +0.6% on the higher side. Passing–Bablok regression yielded a slope of 1.036 and an intercept of –1.422. There is no significant proportional bias between the two methods. However, the intercept suggested the presence of a constant negative bias. Although PEIT correlates strongly with HPLC, it consistently underestimates HbA1c, particularly at higher concentrations. While the negative bias suggests a systematic underestimation, the relatively wide limits of agreement highlight the potential clinical impact, particularly around diagnostic and therapeutic decision cut-offs. Therefore, caution is warranted when interpreting HbA1c results near threshold values.

View source

Similar papers

Oct 2026

A-180 Measurement of hemoglobin A1c across three methodologies: A comparison in the presence and absence of hemoglobin variants

The D-100, Alinity, and Roche platforms demonstrated high comparability in HbA1c samples without hemoglobin variants and in the presence of variants, particularly elevated HbF, both Alinity and Roche showed modest negative proportional bias relative to D-100 but maintained a strong correlation.

M. Berman, Casey Williamson, P. Cheng et al. · 0 citations
Oct 2026

B-011 Evaluation of the Tosoh HLC-723GR01 HbA1c Analyzer Using Normal Hemoglobin Samples and in the Presence of Common Hemoglobin and Thalassemic Variants

HbA1c is used to aid in the diagnosis of diabetes, identify individuals at risk for diabetes, and monitor long-term glycemic control. Venous whole blood collected in K2EDTA tubes from normal hemoglobin (HbAA) specimens (n=135) spanning 4.2%–16.6% HbA1c was tested as both whole blood and corresponding hemol...

S. Hanson, Ian L. Gunsolus, K. Kabytaev · 0 citations
Open access Nov 2026

P-338: HbA1c overestimates glycemic burden compared to glucose management indicator in type 1 diabetes

In most participants, HbA1c exceeded GMI, revealing a predominantly unidirectional discrepancy whose magnitude surpassed previously reported rates, consistent with the proportional bias observed and the high baseline glycemic burden of this cohort, with direct implications for therapeutic decision-making.

S. Lemos, G. L. Torres, L. P. S. Lima et al. · 0 citations
Open access Oct 2026

Method comparison and agreement of a fluorescence immunoassay-based HbA1c test with a routine HPLC method

The TRUSTlight FIA showed a small mean bias relative to the HPLC comparator, although the observed limits of agreement were wider than the ± 5% NGSP manufacturer certification criterion, which is wider than the ± 5% NGSP manufacturer certification criterion.

Harresh Adikesavalu, Neema Raja Beaulah Budithi, S. Ramanathan et al. · 0 citations
Oct 2026

B-059 Precision and Bias Verification of HbA1c by HPLC Following CLSI EP15-A3 in a Hospital Laboratory in Manabí, Ecuador

Glycated Hemoglobin (HbA1c) is a key biomarker for the diagnosis and monitoring of diabetes mellitus, reflecting the average blood glucose over the past 2–3 months. The clinical reliability of the results depends on the proper analytical performance of the method, particularly in terms of precision and bias, whic...

Jorge A. Zambrano, Ana Alcívar, Ivón Howland · 0 citations