Skip to content
Open access

P-338: HbA1c overestimates glycemic burden compared to glucose management indicator in type 1 diabetes

Nov 2026 · Hormone Research in Paediatrics · 0 citations

TL;DR

In most participants, HbA1c exceeded GMI, revealing a predominantly unidirectional discrepancy whose magnitude surpassed previously reported rates, consistent with the proportional bias observed and the high baseline glycemic burden of this cohort, with direct implications for therapeutic decision-making.

Abstract

Glycated hemoglobin (HbA1c) and glucose management indicator (GMI) derived from continuous glucose monitoring (CGM) estimate glycemic control through distinct mechanisms. Whether GMI can reliably substitute HbA1c in clinical decision-making for type 1 diabetes (T1D) remains uncertain. To evaluate the agreement between laboratory HbA1c and CGM-derived GMI at six months, and to explore the association between time in range (TIR) and HbA1c in individuals with T1D. A 6-month longitudinal study enrolled 53 individuals with T1D from a public endocrinology clinic in Northeastern Brazil. All participants used an intermittently scanned CGM. HbA1c was measured at baseline and at six months. Agreement between HbA1c and GMI at six months was assessed using the Bland-Altman method, intraclass correlation coefficient (ICC), and Pearson correlation. The association between TIR and HbA1c was assessed by linear regression. A total of 32(60.4%) of participants were under 25 years of age. Baseline HbA1c was 9.06±1.86%, diabetes duration was 11±8.72 years, and GMI at six months was 7.64±1.04%. Agreement between HbA1c and GMI was poor: mean bias was +0.80% (HbA1c systematically higher than GMI), with proportional bias indicating greater discrepancy in participants with worse glycemic control. Only 27% showed agreement within 0.5%, while 32% had discrepancies above 1%. ICC was moderate (0.616), despite strong Pearson correlation (r=0.838). TIR and HbA1c showed strong negative correlation (r=-0.789; R2=0.62), with each 10% increase in TIR corresponding to a 0.8% reduction in HbA1c. HbA1c and GMI are not interchangeable in this population. In most participants, HbA1c exceeded GMI, revealing a predominantly unidirectional discrepancy whose magnitude surpassed previously reported rates, consistent with the proportional bias observed and the high baseline glycemic burden of this cohort, with direct implications for therapeutic decision-making.

Read PDF

Similar papers

Open access Oct 2026

A Comparative Analysis Between Original and Updated Glucose Management Indicator and Glycated Haemoglobin Across Continuous Glucose Monitoring Sensors in Type 1 Diabetes.

AIMS The continuous glucose monitoring (CGM)-derived glucose management indicator (GMI) is used for estimating glycated haemoglobin (HbA1c). This study assessed agreement between GMI-calculated using both original and updated (uGMI) models-and laboratory-measured HbA1c across Dexcom, MiniMed and Abbott sensors. MATER...

Lavanta Farouk, Bilal Bashir, R. Seese et al. · 0 citations
Open access Oct 2026

Association Between the GMI/HbA1c Ratio and Microvascular Complications in Type 1 Diabetes: A Multicenter Cross-Sectional Study.

OBJECTIVE To clarify whether the glucose management indicator (GMI)/glycated haemoglobin (HbA1c) ratio (GMI/HbA1c ratio) is an independent predictor of microvascular complications in Type 1 diabetes (T1D). DESIGN AND METHODS Multicentre, cross-sectional, observational study including subjects with T1D with at least 5...

Sandra Herranz-Antolín, M. A. Martínez-Brocca, G. Cánovas-Molina et al. · 0 citations
Review Open access Oct 2026

Achieving HbA1c Reduction in Diabetes Management

Objective. To evaluate the effectiveness of continuous glucose monitoring (CGM) compared to point-of-care (POC) glucose testing in reducing HbA1c among adults with diabetes. Methods. This single-center, retrospective cohort study included adult patients with type 1 or type 2 diabetes attending Bayhealth Sussex Endocrin...

Eshita Sharmin, Cameron Golden, Ejaz Mahmood · 0 citations
Open access Nov 2026

P-346: Age at type 1 diabetes diagnosis independently predicts glycemic response to continuous glucose monitoring in a low-income population

Continuous glucose monitoring (CGM) access in Brazil remains limited and fragmented, with isolated initiatives that often prioritize specific subgroups. Identifying predictors of glycemic response may support more equitable prioritization strategies. To identify clinical and sociodemographic predictors of...

S. Lemos, G. L. Torres, L. P. S. Lima et al. · 0 citations
Open access Nov 2026

P-141: Beyond HbA1c: impact of therapeutic education and continuous glucose monitoring in pediatric type 1 diabetes

Therapeutic patient education (TPE) is central to pediatric type 1 diabetes (T1D) management. Its impact on dynamic glycemic metrics — time in range, variability, and circadian patterns — remains underexplored. This study evaluates the combined effect of structured TPE and continuous glucose monitoring (CGM) with...

D. Senouci, A. S. Bendeddouche · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.