TL;DR
A dataset from a wearable sensor that monitors respiration, electrocardiography, body position/actigraphy, and skin temperature, suitable for sleep studies is presented, and broad agreement between standard metrics used to assess sleep quality measured from the wearable sensor and the resident polysomnography system is shown.
Abstract
We present a dataset from a wearable sensor that monitors respiration, electrocardiography (one lead), body position/actigraphy, and skin temperature, suitable for sleep studies. We collected the dataset in parallel with standard in-laboratory polysomnography (PSG) and used it to validate ASPEN-derived metrics against clinical assessments. Data were collected from seven volunteers (mean age = 55.7 ± 12.5 years and body mass index (BMI) = 29.9 ± 3.78 kg/m2) for a total of 63 h during sleep studies at the Flinders University Sleep Lab. Our preliminary analysis shows broad agreement between standard metrics used to assess sleep quality measured from the wearable sensor and the resident (Compumedics) polysomnography system, such as respiratory rate, heart rate, and sleep posture. Therefore, we make this dataset of high-resolution ASPEN signals, along with synoptic participant data (age, gender, BMI), available to support the development and benchmarking of algorithms for wearable sleep monitoring.
Sleep disturbance is an established hypertension risk factor. However, prior studies relied on self-reported or single-night polysomnographic data, precluding dynamic long-term evaluation. Conventional ambulatory monitoring cannot concurrently quantify sleep. The smartwatch sphygmomanometer enable simultaneous ca...
Y. Liu, Z. Lv, Y. Wang et al.· European Heart Journal· 0 citations
Preliminary evidence is provided that surface TASs can recover an RIP-trough-derived operational phase landmark in unseen same-center participants, and independent multimodal adjudication, external replication, and full-night causal testing are required before clinical or respiratory-synchronized HGNS applications.
Meng-Shuang Lv, Jian-Hong Liao, Yun-Han Shi et al.· Bioengineering· 0 citations
These findings support the use of wearable devices for scheduled spot-check cardiovascular assessment under controlled conditions and underscore the need for standardized measurement protocols before their implementation in ambulatory or long-term monitoring applications.
Octavio A. Lecona, V. Martínez-Garcés, B. Estañol et al.· Healthcare· 0 citations
Wrist PPG reliability is condition dependent, and an interpretable signal-based reliability flag may complement point heart-rate estimates, and an interpretable signal-based reliability flag may complement point heart-rate estimates in previously unseen participants.
Angel Xu· Theoretical and Natural Scie...· 0 citations
Background Consumer wearables and continuous glucose monitors (CGM) are increasingly worn together outside clinical settings. Few studies have examined whether two wearables worn at the same time agree with each other, and whether either tracks glucose metrics derived from CGM. Objective In one adult under free-living...
M. Lovrić, M. Rasmussen, Dejan Strbad· bioRxiv· 0 citations
BACKGROUND AND OBJECTIVE
Surface electrogastrography records gastrointestinal myoelectric activity non-invasively from the abdominal surface. Despite decades of investigation, clinical adoption remains limited by low signal-to-noise ratio, motion artifacts, and the lack of standardized public datasets. This work presen...
Rodrigo Braga, S. Sousa, Nian-Fei Ao et al.· Computer Methods and Program...· 0 citations