Evaluation of Blood Pressure and Heart Rate Measurements from Smartwatch HUAWEI WATCH D2 Data: A Preliminary Report

Oct 2026 · Healthcare · 0 citations · 24 references

TL;DR

These findings support the use of wearable devices for scheduled spot-check cardiovascular assessment under controlled conditions and underscore the need for standardized measurement protocols before their implementation in ambulatory or long-term monitoring applications.

Abstract

Background/Objectives: Wearable devices offer a scalable approach to repeated cardiovascular assessment through ambulatory spot measurements and have demonstrated adequate performance in measuring heart rate (HR). However, their reliability for blood pressure (BP) assessment remains uncertain. This study aimed to evaluate BP and HR measurements obtained with the HUAWEI WATCH D2 smartwatch by comparison with standard reference devices under controlled postural conditions. Methods: A total of 30 participants (15 women and 15 men; age range, 21–88 years) were enrolled. One participant could not undergo smartwatch measurement because of wrist-size limitations, and measurement acquisition failed in another participant. Consequently, paired measurements obtained in the seated and upright positions were analyzed for 28 participants. Smartwatch-derived systolic BP (SBP), diastolic BP (DBP), and HR were compared with a digital sphygmomanometer, an analog sphygmomanometer, and a digital pulse oximeter. Agreement was assessed using percentage error and Bland–Altman analysis, complemented by linear regression to evaluate proportional bias. Results: In the seated position, the smartwatch showed agreement with percentage errors below 4% for SBP and DBP, with concordance coefficients indicating good agreement. In the upright position, accuracy decreased, with percentage errors up to 14%, increased variability, wider limits of agreement, and the presence of systematic and proportional discrepancies. Measurement performance was influenced by device placement, and isolated failures highlighted sensitivity to anatomical and technical factors. Conclusions: Smartwatch-based BP monitoring is feasible under controlled conditions but remains dependent on posture and measurement conditions. These findings support the use of wearable devices for scheduled spot-check cardiovascular assessment under controlled conditions and underscore the need for standardized measurement protocols before their implementation in ambulatory or long-term monitoring applications.

Read PDF

Similar papers

Open access 2025

Impact of physical exercise on the accuracy of blood pressure and heart rate data measured by smartwatch

INTRODUCTION: Heart rate (HR) and blood pressure (BP)—systolic (SBP) and diastolic (DBP)—are important for individuals who engage in physical activity. Smartwatches stand out because they are convenient and collect data noninvasively; however, the information they provide during physical exercise still requires validat...

Julia Basolli Gomiero, Gustavo D'Annibale Bech, Thiago Song Won Yoon et al. · 0 citations
Open access Sep 2026

Effect of exercise-induced short-term changes in blood pressure and heart rate on smartwatch measurement accuracy

Blood pressure (BP) is a key vital sign that many people around the world are increasingly monitoring continuously using smartwatches. It remains unclear whether smartwatches can fully replace traditional oscillometric cuff-based devices under real-world conditions. The aim of this study was to verify the accuracy of B...

Veronika Ráfl Huttová, Šimon Walzel, M. Rožánek et al. · 0 citations
Open access Oct 2026

Validation of a wrist-worn dual-sensor applanation tonometry device for blood pressure measurement under rest and stress conditions

Wrist-based cuffless blood pressure (BP) monitoring offers potential advantages for longitudinal and ambulatory assessment but has been limited by signal instability and measurement variability, particularly under physiologically dynamic conditions. We evaluated the agreement between a novel wrist-worn blood pres...

M. Jung, H. Lim · 0 citations
Open access Oct 2026

Sleep parameters derived from smartwatch sphygmomanometer are associated with systolic blood pressure and time in therapeutic range: a large-scale real-world longitudinal study

Sleep disturbance is an established hypertension risk factor. However, prior studies relied on self-reported or single-night polysomnographic data, precluding dynamic long-term evaluation. Conventional ambulatory monitoring cannot concurrently quantify sleep. The smartwatch sphygmomanometer enable simultaneous ca...

Y. Liu, Z. Lv, Y. Wang et al. · 0 citations
Open access Sep 2026

Validation study on cuffless ambulatory blood pressure monitoring method using bio-impedance, impedance cardiography and electrocardiography.

PURPOSE Continuous, non-invasive blood pressure (BP) monitoring is essential for understanding cardiovascular dynamics in real-world settings. This study evaluated the reliability and validity of a cuffless method for ambulatory BP monitoring using pulse wave travel times derived from bio-impedance, impedance cardiogra...

Myrte Schoenmakers, Martin J. Gevonden, B. Sauce et al. · 0 citations
Open access Sep 2026

Long-Term Stability and Blood Pressure Change Tracking with a Cuffless Wearable Device in Hypertensive Patients.

CSEM's wearable PPG-based cuffless BP monitor appears to provide stable BP estimation and concordant tracking of week-to-month BP changes during antihypertensive therapy when compared with an oscillometric device, and could support the clinical acceptance of PPG-based wearable BP monitors.

M. Proença, Pierre-Antonin Rigon, G. Bonnier et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.