Oct 2026· Bioengineering· Vol 13· 0 citations· 53 references
Medicine
TL;DR
Preliminary evidence is provided that surface TASs can recover an RIP-trough-derived operational phase landmark in unseen same-center participants, and independent multimodal adjudication, external replication, and full-night causal testing are required before clinical or respiratory-synchronized HGNS applications.
Abstract
Reliable respiratory phase sensing is important for respiratory-synchronized hypoglossal nerve stimulation (HGNS), but conventional sensing approaches may impose additional burden. This pilot study investigated whether a surface triaxial accelerometry sensor (TAS) could detect thoracic respiratory inductance plethysmography (RIP) troughs, which were used as operational phase landmarks representing the transition from end expiration to subsequent inspiration, rather than as directly established physiological respiratory onsets. Ten participants underwent synchronized overnight polysomnography and surface TAS recording, providing 5377.3 min of analyzable data and 75,499 automatically generated RIP landmarks. Two complementary Conformer models were trained using Gaussian weak labels and combined using multi-offset dual-conformer fusion. Generalization was evaluated using outer leave-one-subject-out validation, with fusion weights and event thresholds selected from training-side validation data. At a ±1.0 s matching tolerance, the fusion achieved participant-mean precision, recall, and F1 scores of 0.78, 0.82, and 0.80, respectively, with a 95% confidence interval of 0.75–0.85 for the mean F1 score. It outperformed each component model in 9 of 10 participants; however, its F1 gain over otherwise identical single-grid fusion was 0.0036, below the prespecified exploratory advancement margin. These findings provide preliminary evidence that surface TASs can recover an RIP-trough-derived operational phase landmark in unseen same-center participants. Independent multimodal adjudication, external replication, and full-night causal testing are required before clinical or respiratory-synchronized HGNS applications.
A dataset from a wearable sensor that monitors respiration, electrocardiography, body position/actigraphy, and skin temperature, suitable for sleep studies is presented, and broad agreement between standard metrics used to assess sleep quality measured from the wearable sensor and the resident polysomnography system is...
Benjamin M. Brandwood, G. Naik, P. Breen et al.· The Scientist· 0 citations
Abstract Background Respiratory inductance plethysmography (RIP) belts are the standard for measuring thoracoabdominal movements in home sleep apnea testing (HSAT), but are often cumbersome and power-intensive. Objective This study aimed to characterize abdominal movement signals measured by a wireless, single-point, a...
T. H. Dang, N. Sung, Hyung-Ki Min et al.· JMIR Formative Research· 0 citations
Findings of SeqSmoother reveal an accuracy-availability trade-off between learned temporal modeling and quality-gated signal processing while providing empirical support for a physics-informed approach to identifying frequency-tracking failures in accelerometer-based sleep HR estimation.
Tanbin Islam Rohan, P. Gupta, Tanusree Debi et al.· 0 citations
Obstructive sleep apnea (OSA) affects nearly one billion people worldwide, yet diagnosis remains bottlenecked by labor-intensive polysomnography. This study presents a cross-platform deployment case study of a lightweight Temporal Convolutional Network with Squeeze-and-Excitation attention (TCN-SE, 183K parameters), us...
Jong-Gan Song, U. Erdenebayar· IEEE Access· 0 citations
BACKGROUND AND OBJECTIVE
Surface electrogastrography records gastrointestinal myoelectric activity non-invasively from the abdominal surface. Despite decades of investigation, clinical adoption remains limited by low signal-to-noise ratio, motion artifacts, and the lack of standardized public datasets. This work presen...
Rodrigo Braga, S. Sousa, Nian-Fei Ao et al.· Computer Methods and Program...· 0 citations
Wrist PPG reliability is condition dependent, and an interpretable signal-based reliability flag may complement point heart-rate estimates, and an interpretable signal-based reliability flag may complement point heart-rate estimates in previously unseen participants.
Angel Xu· Theoretical and Natural Scie...· 0 citations