This paper develops a three-dimensional refined finite-element model for the typical concrete lining of the Dianzhong Water Diversion Project tunnel, investigates the temperature and stress fields of the lining, and systematically analyzes the influences of various temperature-control measures and construction conditions on both fields. The interface between the surrounding rock and the lining is simulated using thin-layer contact elements. The results show that the rock temperature beyond a depth of 6 m is not affected by concrete hydration. The maximum temperature of the lining poured in the inner section is 6.36 °C higher than that poured at the entrance section. Concrete with micro-expansion and low adiabatic temperature rise, as well as pouring during low-temperature seasons, is beneficial for the anti-cracking safety degree of the lining. The temperature stress increases with the pouring temperature: when the pouring temperature rises by 4 °C, the minimum cracking safety factor decreases by 0.25. For this project section, the appropriate segmented length of the lining structure ranges from 8 m to 10 m. These results can provide guidance for the construction of tunnel linings to improve their anti-cracking safety degree.
Roller compacted concrete (RCC) is widely used in large-scale hydraulic structures, but its high heat of hydration and poor heat dissipation can easily cause temperature cracks, posing a threat to engineering safety. Traditional temperature control measures mainly focus on post-event cooling, which are passive, sin...
Water loads on subsea tunnel linings are governed by the combined effects of seepage, structural deformation, and the grouting zone. However, these factors are often treated separately in existing analytical studies. In this study, an analytical model is developed for steady-state saturated seepage around a deep-buried...
Jian Wang, Xiu-Ying Wang, Zhong-Sheng Tan et al.· Water· 0 citations
When designing and constructing massive concrete hydraulic structures, it is necessary to maintain the temperature regime of structures that ensure crack resistance. Crack resistance depends on the possibility of internal tensile stresses. To eliminate this, it is necessary to take measures to regulate the temperature...
Y. Bik, Nyailya N. Fomicheva· Russian Journal of Water Tra...· 0 citations
To investigate the feasibility of constructing roller-compacted concrete (RCC) dams with an unconventional lift thickness of 13.5 m in high-temperature seasons, a 3D finite element model of a typical dam block of an RCC gravity dam was established. Based on concrete material parameters and field-measured temperature da...
Wei-Qin Wang, Xin-Lu Zhang, Jian-Peng Li et al.· International Conference on...· 0 citations
The work investigates the influence of the level of applied mechanical load on the fire resistance limit of a reinforced concrete wall under the conditions of a standard temperature fire regime. For this purpose, a geometric and finite element model of a wall fragment was developed, taking into account the joint operat...
S. Sidnei, I. Ishchenko, Roman Motrichuk et al.· Advances in Science and Tech...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.