Skip to content
Open access

Full-process temperature control and crack prevention of roller compacted concrete in water conservancy projects

Sep 2026 · Frontiers of Mechanical Engineering · 0 citations · 18 references

Abstract

Roller compacted concrete (RCC) is widely used in large-scale hydraulic structures, but its high heat of hydration and poor heat dissipation can easily cause temperature cracks, posing a threat to engineering safety. Traditional temperature control measures mainly focus on post-event cooling, which are passive, single and have limited effects. There is also a lack of systematic coupling of the inherent thermal properties of materials and the dynamic construction process. Therefore, this paper conducted a model test for the optimization of full-process temperature control and crack prevention, aiming to suppress the generation of temperature cracks at the source and provide a reference for the temperature control and crack prevention design and construction of RCC in water conservancy projects. This paper used a 1:40 geometrically scaled block model to simulate the large-volume RCC structure of an actual gravity dam and made a similarity analysis on from aspects of geometry, hydration heat, temperature, cooling aging, stress, and cracking behavior. A reference group (G0), five single-factor optimization groups (G1 mix proportion optimization condition, G2 mixing temperature control condition, G3 pouring technique condition, G4 internal cooling condition, G5 post-curing condition), and one full-process integrated optimization group (G6) were set up. Five specimens were prepared for each group. The pouring and curing process was carried out in an environmental chamber under summer conditions. Temperature and stress data from 0 to 40 days were collected using pre-installed T-type thermocouples and vibrating wire strain gauges. Images of the surface cracks of the specimens were captured using an industrial camera and quantitatively analyzed. The evaluation indicators included maximum center temperature, maximum internal and external temperature difference, cooling rate, first crack time, total crack area, maximum crack width, maximum tensile stress, occurrence time, stress reserve coefficient. Each single optimization measure could reduce temperature rise, decrease temperature difference, and delay cracking to varying degrees, but the paths and magnitudes of their effects were different. G2 had a remarkable effect in reducing the peak internal temperature; G3 performed excellently in reducing temperature difference and delaying cracking; G4 had a fast cooling rate but was prone to generating secondary temperature differences, and using it alone limited anti-cracking effect; G5 had the least effect on temperature control and crack prevention. G6 had the best effect, with the peak temperature in the center being 15.4 °C lower than G0, the maximum internal and external temperature difference being only 15.1 °C, the maximum tensile stress being only 0.98 MPa, and the stress reserve coefficient reaching 1.43. No cracking occurred within the 40-day observation period. The internal temperature rise of RCC is caused by the exothermic hydration reaction of cement and fly ash. Different optimization measures have fundamentally different paths for suppressing the hydration heat. The single-factor optimization group can only address the shortcomings of a single temperature control link and cannot simultaneously meet the control conditions of low temperature rise, small gradient, slow cooling, and low stress; the full-process integrated optimization G6 forms a closed-loop temperature control system through the collaborative effect of various temperature control measures to achieve the optimal effect of no cracking within 40 days. The research results can provide references for material ratio, layered pouring, water supply cooling, and intelligent monitoring in the construction of gravity dams made of RCC.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.