Skip to content
Conference

Temperature control and thermal stress feedback analysis of unconventional layer thickness pouring for roller compacted concrete gravity dam

Sep 2026 · International Conference on Optics, Electronics, and Communication Engineering · Vol 14349, pp. 143493S - 143493S-9 · 0 citations · 11 references
Engineering

Abstract

To investigate the feasibility of constructing roller-compacted concrete (RCC) dams with an unconventional lift thickness of 13.5 m in high-temperature seasons, a 3D finite element model of a typical dam block of an RCC gravity dam was established. Based on concrete material parameters and field-measured temperature data, feedback analysis was conducted on the temperature field and thermal stress of concrete with the 13.5 m unconventional lift thickness, and a comparison was made with the conventional 9 m lift thickness condition. The results show that with thermal control measures, the maximum temperature and thermal stress of the 13.5 m lift thickness concrete reach 28.4 °C and 0.75 MPa, respectively, with the anti-cracking safety factor meeting thermal control and crack prevention requirements. The 13.5 m lift thickness concrete has a 2 °C higher maximum temperature but a 0.11 MPa lower maximum thermal stress than the 9 m one, mainly due to its higher placement elevation leading to weaker foundation constraints and thus reduced thermal stress. This study verifies that appropriately increasing the RCC lift thickness in the unconstrained zone is feasible under the premise of timely and stable water cooling with qualified water temperature and flow rate.

View source