Jul 2026· 2026 5th International Conference on Energy and Electrical Power Systems (ICEEPS)· pp. 72-79· 0 citations· 16 references
Abstract
Accurate line-loss diagnosis and loss-reduction control are essential for low-voltage distribution transformer areas under high penetration of distributed energy resources (DERs). With electric vehicles (EVs), rooftop photovoltaic (PV) generation, and energy storage systems (ESS) connected at the customer side, traditional line-loss patterns are reshaped by bidirectional power flow, evening-concentrated charging behavior, voltage rise, and local flexibility. To address both abnormal-loss identification and operational mitigation, this paper proposes an integrated framework for transformer-area line-loss governance. First, the physical and operational factors affecting technical and non-technical line losses are analyzed, and simulation-supported sensitivity intervals are linked to DER penetration, power factor, load rate, and feeder impedance. Second, a two-stage anomaly diagnosis scheme is constructed, in which Isolation Forest screens suspicious samples from a 20-dimensional feature matrix and XGBoost classifies the detected abnormal samples into electricity theft, equipment failure, metering error, and topology error. Third, a collaborative loss-reduction strategy coordinates ESS dispatch, ordered EV charging, and PV hosting-capacity screening through time-series MATPOWER AC power-flow calculation. Case studies on a 500-household transformer area and the IEEE 69-bus radial feeder implemented in MATPOWER show that the classification stage achieves 99.02% accuracy and a macro-F1 score of 0.9917. The coordinated strategy selected by enumerative search reduces daily line loss by 25.3%-28.6%, with an average reduction of 27.1%, while reducing the maximum voltage deviation from 6.8% to 2.9%. The results demonstrate that combining data-driven diagnosis with DER-aware operational optimization can provide practical support for high-loss station governance in new power systems.
The growth of electric vehicles (EVs) and photovoltaic (PV) generation introduces new operational challenges for low voltage (LV) distribution networks, including transformer overloading, voltage deviations and bidirectional power flows. Mitigation measures often include the upgrading of conventional transformers and t...
Kittiphonh Phengthavongsa, Daniel Burmester· Archives of Sustainable Ener...· 0 citations
With the increasing penetration of distributed renewable energy and flexible loads, distribution networks face higher requirements for coordinated safe, economic and green operation. Traditional monitoring methods mainly focus on safety violations, while economic and low-carbon operation deviations are not sufficiently...
Long-Bo Luo, Meng Ye, Cheng Shi et al.· 2026 6th Power System and Gr...· 0 citations
Excessive reactive power transmission and three-phase imbalance cause heavy distribution network loss and voltage violations. Traditional fixed-weight multi-objective Volt-VAR modules in GridLAB-D cannot dynamically coordinate loss reduction and voltage regulation, and most existing studies only adopt small-scale test...
Hai-Feng Wu, Hao Gu, Xian-Song Bao et al.· Journal of Physics, Conferen...· 0 citations
The way power systems operate is being reshaped by the high penetration of distributed energy resources (DERs) such as rooftop solar, batteries and electric vehicles in low-voltage distribution networks. These technologies, although beneficial for decentralization and decarbonization, pose significant technical challen...
Mariam Mujtaba, Daniel Burmester· Archives of Sustainable Ener...· 0 citations
Enhancing observability and energy efficiency of 0.4 kV distribution networks is a priority objective in the digitalization of the power sector. Traditional solutions based on digital substations are economically unfeasible for numerous low-voltage facilities. This paper proposes a comprehensive approach utilizing data...
R. Belousov, E. S. Latypov, A. Nikolaev et al.· LETI Transactions on Electri...· 0 citations
INTRODUCTION: High penetration of inverter-based distributed generators (IBDGs) changes power-flow patterns and fault transients in distribution networks, reducing the effectiveness of conventional outage identification. Under the adopted low-voltage ride-through control model, IBDG fault currents are limited to 1.2–1....
Ning Liu, Xiao-Peng Zhang, Xu-Dong Wang et al.· EAI Endorsed Transactions on...· 0 citations