Sep 2026· Archives of Sustainable Energy Systems· 0 citations· 56 references
Abstract
The growth of electric vehicles (EVs) and photovoltaic (PV) generation introduces new operational challenges for low voltage (LV) distribution networks, including transformer overloading, voltage deviations and bidirectional power flows. Mitigation measures often include the upgrading of conventional transformers and the re-conductoring of feeders. These methods become inefficient for uncertain load-growth paths. The technical effectiveness of coordinated distributed energy resources (DERs), such as rooftop PV systems, battery energy storage systems (BESS), and EV charging as non-wires alternatives (NWAs) to reduce the operational stress on local distribution transformers (LDTs) is assessed in this study. The representative Wellington suburban LV feeder is a 656-household feeder with 500-1000 kVA transformers. The feeder is modelled in DIgSILENT PowerFactory 2024 using the quasi-dynamic simulation language (QDSL) time-series at hourly resolution for one year. Four progressive scenarios are considered: (i) baseline operation without DERs, (ii) increasing PV penetration levels (5% in 2030, 10% in 2035, 28% in 2050), (iii) increasing number of EVs as load (5% in 2030, 10% in 2035, 28% in 2050) and (iv) integration of community-scale BESS for peak shaving. The results show that coordinated operation of DERs with BESSs can reduce transformer peak loading and improve voltage compared to standalone PV. In particular, the transformer-aware BESS dispatch offers a measurable peak shaving capacity and improves the local energy balancing, enabling a higher renewable penetration with less conventional infrastructure reinforcement. The practical role of DER coordination in improving LV network are more resilience and defers investment in the distribution systems as a scalable approach.
Electric vehicle (EV) adoption in Sri Lanka is accelerating rapidly, with a large number of new registrations in 2025 alone. This surge poses significant challenges to residential distribution networks, particularly in high density areas. Uncoordinated home charging stresses distribution transformers through increased...
M. H. Dasanayake, C. Yapa· Moratuwa Engineering Researc...· 0 citations
The increasing deployment of building-scale photovoltaic (PV) systems can influence power factor (PF) performance in electrical distribution networks, especially when reactive power demand is not properly compensated. Poor PF can increase apparent power demand, reduce distribution system efficiency, and expose consumer...
M. Amirudin, Elia Erwani Hassan, Z. M. Yasin et al.· International Journal of Adv...· 0 citations
The way power systems operate is being reshaped by the high penetration of distributed energy resources (DERs) such as rooftop solar, batteries and electric vehicles in low-voltage distribution networks. These technologies, although beneficial for decentralization and decarbonization, pose significant technical challen...
Mariam Mujtaba, Daniel Burmester· Archives of Sustainable Ener...· 0 citations
Aotearoa New Zealand’s distribution network faces significant strain from a 250% increase in distributed solar photovoltaic installations between 2013 and 2022. These trends increase vulnerability to failure of line-frequency transformers (LFT). The objective of this paper is to investigate the technical feasibility of...
Ngonidzashe Mushayi, Daniel Burmester· Archives of Sustainable Ener...· 0 citations
The German low-voltage (LV) distribution grid faces stress from the build-out of distributed photovoltaic (PV) units. Battery storage is widely proposed as a solution, yet the literature is partitioned by storage scale, placement, and how ageing is treated. This study introduces a unified cross-class assessment of the...
Sebastian Zurmühlen, Jonas Brucksch, D. U. Sauer· Energy Storage and Applicati...· 0 citations
The increase in electricity demand of Nigerian universities, with an epileptic public grid, has created interest in integrating solar photovoltaic (PV) generation into distribution networks. This study presents a load-flow assessment of the 11 kV/0.415 kV distribution network of the Federal University of Technology, Ak...
A. J. Sotomiwa, M. R. Adu· International journal of re...· 0 citations