Insulin delivery characteristics and glycemic control in older adults with type 1 diabetes using the Minimed™ 780G system: a real-world analysis

Aug 2026 · Frontiers in Endocrinology · Vol 17 · 0 citations · 41 references
Medicine

TL;DR

While the MiniMed™ 780G AID system use is associated with low CGM-derived hypoglycemia exposure and highly effective glycemic control, regardless of customized settings, superior glycemic control is associated with a higher proportion of user-initiated manual boluses.

Abstract

Introduction Diabetes self-management in older adults with type 1 diabetes (T1D) presents a unique clinical challenge, since maintaining tight glycemic control must be carefully weighed against age-related vulnerabilities. This study aimed to analyze glycemic control through the effects of customized algorithm settings in a cohort of older adults with T1D using an automated insulin delivery (AID) system. Methods This retrospective real-world data analysis included users of the MiniMed™ 780G AID system, aged ≥60 years. Continuous glucose monitoring (CGM) data including time in range (TIR; 70–180 mg/dL; 3.9–10.0 mmol/L), time in tight range (TITR; 70–140 mg/dL; 3.9–7.8 mmol/L), time below range (TBR; <70 mg/dL; <3.9 mmol/L), level 2 TBR (<54 mg/dL; <3.0 mmol/L) and time above range (TAR; >180 mg/dL; >10.0 mmol/L) were analyzed alongside algorithm settings and daily insulin use. Group comparisons utilized standard parametric and non-parametric statistical tests. A multivariable logistic regression model identified independent clinical predictors of high glycemic performance (TITR ≥50%). Results The cohort comprised 97 AID users (70.1% female, mean age 67.9 ± 6.7; range 60–90 years). Overall glycemic control was good, with mean TIR 76.1%, TITR 51.1% and TBR 1.1%. Fourteen participants (14.4%) used the manufacturer’s recommended optimal settings (ROS); i.e., target glucose of 5.5 mmol/L and active insulin time of 2 hours. CGM metrics did not differ between ROS and non-ROS users for TIR, TITR and TBR. When stratifying the cohort by glycemic performance, 55 participants (56.7%) reached TITR ≥50%; however, the adoption of ROS in high (≥50%) TITR and lower (<50%) TITR subgroups was similar (16.4% vs 11.9%; Fisher p=0.58). When compared to the lower TITR subgroup, participants in the high TITR subgroup delivered less auto-correction insulin (14.2% vs 20.6%, p<0.001) and a higher proportion of manual bolus insulin (46.1% vs 35.2%, p<0.001), which remained a significant predictor of high TITR after multivariable adjustment. TBR was significantly higher in the high (≥50%) TITR subgroup, although it remained low in absolute terms (1.5% vs. 0.8%; p=0.017). Conclusion While the MiniMed™ 780G AID system use is associated with low CGM-derived hypoglycemia exposure and highly effective glycemic control, regardless of customized settings, superior glycemic control is associated with a higher proportion of user-initiated manual boluses. The algorithm supports, but cannot replace, user engagement.

Read PDF

Similar papers

Aug 2026

Continuous Glucose Monitoring and Automated Insulin Delivery in Infants with Type 1 Diabetes: Real-World Evidence to Support Future International Guidelines.

CGM is safe in very young children, with AID systems proving superior to traditional therapy, and real-world evidence supports incorporating AID consideration into future international guidelines from the time of pediatric diagnosis.

M. Marigliano, A. Scaramuzza, C. Arnaldi et al. · 0 citations
Open access Oct 2026

Time in Range as a Marker of Concurrent Glycemic and Lipid Improvement in Adults with Type 2 Diabetes: A Real-World Retrospective Pre–Post Study

This study aims to evaluate whether continuous glucose monitoring (CGM)-derived time in range (TIR) attainment is associated with concurrent improvements in glycemic control and lipid profiles among adults with type 2 diabetes mellitus (T2DM). In this retrospective, single-arm pre–post study, 542 adults with T2DM who u...

Mi-Joon Lee, B. Seo, J. Cho · 0 citations
Review Sep 2026

Glycemic and psychosocial outcomes of automated insulin delivery in older and high-risk populations with type 1 diabetes: a systematic review and meta-analysis.

Automated insulin delivery exhibits favorable glycemic outcomes and safety profiles in older and high-risk individuals with type 1 diabetes, suggesting potential benefits for populations traditionally considered vulnerable, although no significant improvements were observed in psychosocial outcomes.

Puguh Oktavian, Citrawati Dyah Kencono Wungu, I. Amin et al. · 0 citations
Aug 2026

Glycemic and safety outcomes of the insulin-only bionic pancreas in older adults and individuals with impaired awareness of Hypoglycemia: a post hoc analysis of a randomized pivotal trial.

AIMS Evaluate the efficacy and safety of iLet Bionic Pancreas (BP) in older adults and individuals with impaired awareness of hypoglycemia (IAH). METHODS This post hoc analysis used individual participant-level data from the Insulin-Only Bionic Pancreas Pivotal Trial (n = 440; NCT04200313). Eligible participants (n =...

Puguh Oktavian, Citrawati Dyah Kencono Wungu, Indah Mohd Amin et al. · 0 citations
Aug 2026

Technology choice, glycemic control and patient-reported outcome measures in adults with type 1 diabetes: A randomized crossover trial comparing a smart insulin pen with an automated insulin delivery system (EBIACE-1).

AID provides superior glycemic control, although nearly half of participants achieved near-optimal control with SIP, supporting a personalized approach to technology selection.

Teresa Ruiz Gracia, L. Nattero-Chávez, A. Martín et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.