Technology choice, glycemic control and patient-reported outcome measures in adults with type 1 diabetes: A randomized crossover trial comparing a smart insulin pen with an automated insulin delivery system (EBIACE-1).
Aug 2026· Diabetes Research and Clinical Practice· pp.
113505
· 0 citations· 31 references
Medicine
TL;DR
AID provides superior glycemic control, although nearly half of participants achieved near-optimal control with SIP, supporting a personalized approach to technology selection.
Abstract
Aims
To compare glycemic outcomes and patient-reported outcome measures (PROMs) between smart insulin pens (SIP) and an automated insulin delivery (AID) system in adults with type 1 diabetes (T1D), and to identify individuals able to maintain near-optimal glycemic control using SIP.
Methods
EBIACE-1 was a randomized, open-label, crossover trial including 31 adults with T1D. Participants received SIP (InPen™) and AID (MiniMed™ 780G) for 6 months each. Co-primary outcomes were time in range (TIR 70-180 mg/dL) and HbA1c. Treatment effects were assessed using longitudinal models in intention-to-treat (ITT) and per-protocol (PP) analyses. Predictors of near-optimal glycemic control with SIP were evaluated using multivariable logistic regression.
Results
AID improved glycemic control versus SIP, with higher TIR (81 % vs 66 %; +15 %, 95 % CI 10-19; P < 0.001) and lower HbA1c (6.9 % [52 mmol/mol] vs 7.3 % [56 mmol/mol]; -0.4 %, 95 % CI - 0.6 to - 0.3; P < 0.001). Near-optimal glycemic control with SIP was achieved by 12 of 26 participants (46 %). In exploratory analyses, higher baseline diabetes-related life interference was associated with a lower probability of achieving this outcome.
Conclusions
AID provides superior glycemic control, although nearly half of participants achieved near-optimal control with SIP, supporting a personalized approach to technology selection.
BACKGROUND
Although continuous glucose monitoring (CGM) is well established for insulin-treated diabetes, its utility in non-insulin-treated type 2 diabetes (T2D) remains less studied.
OBJECTIVE
To evaluate the short-term clinical and economic outcomes following personal use of CGM in patients with T2D.
METHODS
Thi...
S. Gadd, Connor W. Willis, Ishfaq Rashid et al.· Journal of Managed Care & Sp...· 0 citations
CGM is safe in very young children, with AID systems proving superior to traditional therapy, and real-world evidence supports incorporating AID consideration into future international guidelines from the time of pediatric diagnosis.
M. Marigliano, A. Scaramuzza, C. Arnaldi et al.· Diabetes Technology & Therap...· 0 citations
Automated insulin delivery exhibits favorable glycemic outcomes and safety profiles in older and high-risk individuals with type 1 diabetes, suggesting potential benefits for populations traditionally considered vulnerable, although no significant improvements were observed in psychosocial outcomes.
Puguh Oktavian, Citrawati Dyah Kencono Wungu, I. Amin et al.· Journal of Clinical Endocrin...· 0 citations
Open-source automated insulin delivery shows promise for managing type 1 diabetes, though pediatric efficacy and safety data remain limited. This study aimed to compare real-world glycemic outcomes of open-source automated insulin delivery systems with hybrid closed-loop systems in youth with type 1 diabetes. This retr...
Duha Hejla, K. Hawke, Leah Borovoi et al.· Pediatric Diabetes· 0 citations
Objective To evaluate the association between an individualized exercise management program based on shared decision-making (SDM) and short-term glycemic control, self-care behaviors, and quality of life in patients with type 2 diabetes mellitus (T2DM). Methods This retrospective cohort study used data from electronic...
Ting-Ting Feng, Fengcheng Cai, Shuang-Yan Xu· Frontiers in Public Health· 0 citations
INTRODUCTION
The MiniMed™ 780G (MM780G) advanced hybrid closed-loop system has been shown to help improve glycemic control compared with continuous glucose monitoring plus multiple daily injections of insulin (MDI) in people with type 1 diabetes (T1D). The long-term health economic outcomes with MM780G versus MDI + CGM...
S. Glastras, Meaghan Read, Asli Zeynep Ozdemir Saltik et al.· Advances in Therapy· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.