Open access Aug 2026

Insulin delivery characteristics and glycemic control in older adults with type 1 diabetes using the Minimed™ 780G system: a real-world analysis

Introduction Diabetes self-management in older adults with type 1 diabetes (T1D) presents a unique clinical challenge, since maintaining tight glycemic control must be carefully weighed against age-related vulnerabilities. This study aimed to analyze glycemic control through the effects of customized algorithm settings in a cohort of older adults with T1D using an automated insulin delivery (AID) system. Methods This retrospective real-world data analysis included users of the MiniMed™ 780G AID system, aged ≥60 years. Continuous glucose monitoring (CGM) data including time in range (TIR; 70–180 mg/dL; 3.9–10.0 mmol/L), time in tight range (TITR; 70–140 mg/dL; 3.9–7.8 mmol/L), time below range (TBR; <70 mg/dL; <3.9 mmol/L), level 2 TBR (<54 mg/dL; <3.0 mmol/L) and time above range (TAR; >180 mg/dL; >10.0 mmol/L) were analyzed alongside algorithm settings and daily insulin use. Group comparisons utilized standard parametric and non-parametric statistical tests. A multivariable logistic regression model identified independent clinical predictors of high glycemic performance (TITR ≥50%). Results The cohort comprised 97 AID users (70.1% female, mean age 67.9 ± 6.7; range 60–90 years). Overall glycemic control was good, with mean TIR 76.1%, TITR 51.1% and TBR 1.1%. Fourteen participants (14.4%) used the manufacturer’s recommended optimal settings (ROS); i.e., target glucose of 5.5 mmol/L and active insulin time of 2 hours. CGM metrics did not differ between ROS and non-ROS users for TIR, TITR and TBR. When stratifying the cohort by glycemic performance, 55 participants (56.7%) reached TITR ≥50%; however, the adoption of ROS in high (≥50%) TITR and lower (<50%) TITR subgroups was similar (16.4% vs 11.9%; Fisher p=0.58). When compared to the lower TITR subgroup, participants in the high TITR subgroup delivered less auto-correction insulin (14.2% vs 20.6%, p<0.001) and a higher proportion of manual bolus insulin (46.1% vs 35.2%, p<0.001), which remained a significant predictor of high TITR after multivariable adjustment. TBR was significantly higher in the high (≥50%) TITR subgroup, although it remained low in absolute terms (1.5% vs. 0.8%; p=0.017). Conclusion While the MiniMed™ 780G AID system use is associated with low CGM-derived hypoglycemia exposure and highly effective glycemic control, regardless of customized settings, superior glycemic control is associated with a higher proportion of user-initiated manual boluses. The algorithm supports, but cannot replace, user engagement.

Š. Volčanšek, P. Vidmar, A. Janež et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.