To address uneven temperature and relative humidity distributions, localized heat accumulation, and insufficient air velocity in an enclosed stacked-cage laying hen house, a three-dimensional computational fluid dynamics (CFD) model of the laying hen house was developed using field-measured structural and environmental data, and a porous-media model was established for the cage zone. Model validation showed that the normalized mean square error (NMSE) values for temperature, relative humidity, and air velocity were all below 0.25, confirming the reliability of the CFD model. Through visualization analysis of the contour maps, the problems of uneven airflow distribution in the original ventilation system and significant heat accumulation at the fan end were identified. On this basis, numerical simulations were conducted for six air-inlet configurations by varying two key parameters: air-inlet spacing and air-inlet number. The simulation results showed that, compared with the original model, the configuration with an air-inlet spacing of 1.14 m and a total of 32 air inlets on the two gable walls improved the uniformity of temperature, air velocity, and relative humidity by 18.00%, 10.54%, and 18.38%, respectively, while reducing the mean effective temperature index (ETI) in the cage zone by 0.5 °C. This configuration effectively alleviated localized heat accumulation and improved air-velocity uniformity. These findings provide a theoretical basis and technical support for the structural optimization and environmental regulation of enclosed stacked-cage laying hen houses.
This study analyzes the thermal behavior and airflow characteristics within a confined balcony space under typical hot and humid climatic conditions in Ho Chi Minh City. A computational fluid dynamics (CFD) model was developed and numerically assessed through mesh-independence and convergence analyses, incorporating an...
Hung-Son Dang, Thi-Anh-Tuyet Nguyen, H. Lai· 2026 11th International Conf...· 0 citations
Double-skin façades (DSFs) can moderate heat transfer and airflow between the outdoor environment and the building interior; however, their performance in hot-arid climates is highly dependent on cavity geometry, ventilation arrangement, and the interaction between the airflow and any active cooling surfaces. The objec...
Vanshaj Kaul, H. Chaudhry, J. Calautit· Buildings· 0 citations
The performance of briquette drying systems is strongly influenced by airflow distribution and thermal uniformity within the drying chamber, which are governed by outlet configuration and internal flow patterns. However, limited studies have systematically quantified the effect of exhaust outlet arrangements on the cou...
Indirect solar drying is a widely adopted fish preservation technique in tropical regions, valued for its low energy requirement and capacity to enhance product quality. However, non-uniform airflow and temperature distribution within drying chambers remain persistent design challenges that compromise drying efficiency...
Yvonne Elizalde, Jonathan Perez, Freddie Simeon Jr. et al.· ASEAN Journal of Scientific...· 0 citations
To address uneven air supply among multiple needle tubes during the drying of high-density forage bales, this study investigated the airflow characteristics and structural optimization of the upper and lower air distribution chambers of a needle-type forage dryer. A three-dimensional CFD model was established, and airf...