Optimization Analysis of Thermal Distribution in a Confined Balcony Space Under Air-Conditioning Outdoor Unit Operation Using Taguchi-Based CFD Simulation

Jul 2026 · 2026 11th International Conference on Applying New Technology in Green Buildings (ATiGB) · pp. 1655-1660 · 0 citations · 11 references

Abstract

This study analyzes the thermal behavior and airflow characteristics within a confined balcony space under typical hot and humid climatic conditions in Ho Chi Minh City. A computational fluid dynamics (CFD) model was developed and numerically assessed through mesh-independence and convergence analyses, incorporating an external air domain to ensure realistic boundary conditions. The Taguchi method, combined with analysis of variance (ANOVA), was employed to evaluate the influence of four key factors: number of outdoor units, installation position, ventilation opening ratio, and ambient wind velocity. The results indicate that the number of outdoor units is the dominant factor affecting the average balcony temperature, contributing the largest variation. Ambient wind velocity has a moderate influence, while installation position and ventilation opening ratio exhibit relatively minor effects. The consistency between Taguchi and ANOVA analyses confirms the reliability of the findings. Based on the signal-to-noise (S/N) ratio analysis using the “smaller-thebetter” criterion, the optimal configuration was identified as A1-B2-C1-D1. A verification simulation showed that the model converged and achieved an average temperature of 304.24 K, significantly lower than in the initial simulation cases. The findings highlight the importance of controlling internal heat sources and optimizing airflow pathways to improve thermal conditions in confined balcony spaces. This study provides practical insights into the design and installation of airconditioning systems in urban residential buildings.

View source

Similar papers

Open access Jul 2026

Numerical Analysis of Outlet Number Effects on Temperature Distribution in a Briquette Oven Using CFD

The performance of briquette drying systems is strongly influenced by airflow distribution and thermal uniformity within the drying chamber, which are governed by outlet configuration and internal flow patterns. However, limited studies have systematically quantified the effect of exhaust outlet arrangements on the cou...

Alviani Hesthi, Permata Ningtyas, Siti Duratun et al. · 0 citations
Open access Aug 2026

CFD-Based Simulation and Optimization of Summer Environmental Conditions in Laying Hen Houses

To address uneven temperature and relative humidity distributions, localized heat accumulation, and insufficient air velocity in an enclosed stacked-cage laying hen house, a three-dimensional computational fluid dynamics (CFD) model of the laying hen house was developed using field-measured structural and environmental...

Lili Zhang, Shan-Jie Zhang, Miaomiao Xie et al. · 0 citations
#diffusion models Open access Oct 2026

Numerical Simulation and Optimization of Airflow Distribution Characteristics in the Air Distribution Chamber of a Needle-type Forage Dryer

To address uneven air supply among multiple needle tubes during the drying of high-density forage bales, this study investigated the airflow characteristics and structural optimization of the upper and lower air distribution chambers of a needle-type forage dryer. A three-dimensional CFD model was established, and airf...

X.-T. Liu, R.-Z. Wang, Tai-Chun Ding · 0 citations
Open access Aug 2026

Comparative CFD Analysis of Double-Skin Façade Cavities Under Extreme Hot-Arid Conditions

Double-skin façades (DSFs) can moderate heat transfer and airflow between the outdoor environment and the building interior; however, their performance in hot-arid climates is highly dependent on cavity geometry, ventilation arrangement, and the interaction between the airflow and any active cooling surfaces. The objec...

Vanshaj Kaul, H. Chaudhry, J. Calautit · 0 citations
Open access Aug 2026

Retrofit Optimization of Raised-Floor Plenum Thermal Performance for Energy-Efficient and Sustainable Operation of Non-Standard Campus Data Centers

In response to issues such as disordered airflow distribution and prominent local hotspots in campus non-standard data centers, this study took a non-standard raised-floor air-supply data center at a university in Hangzhou as the research object, and used a combination of on-site measurements and computational fluid dy...

Jinuo Zhang, Zhiyi Wang, G. Jiang · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.