Stress analysis of mandibular implant-supported overdenture retained with bar and ball attachments of different heights: A comparative finite element study
Oct 2026· The Journal of Indian Prosthodontic Society· Vol 26, pp. 349 - 361· 0 citations· 30 references
Medicine
TL;DR
Within the limitations of this finite element study, attachment height and splinting configuration influenced peri-implant stress distribution, and increased attachment height was associated with greater stress magnitudes in both attachment systems.
Abstract
Aim: To evaluate and compare stress distribution patterns in mandibular implant-supported overdenture retained with bar and ball attachment systems at two attachment heights (1 mm and 3 mm) using three-dimensional finite element analysis (FEA). Settings and Design: An in silico comparative three-dimensional finite element analysis study. Materials and Methods: Four three-dimensional finite element models of an edentulous mandible restored with two interforaminal bone-level implants (3.5 × 10 mm) were developed. The models incorporated bar attachments with heights of 1 mm (A1) and 3 mm (A2), and ball attachments with heights of 1 mm (B1) and 3 mm (B2). All materials were assumed to be homogeneous, isotropic, and linearly elastic. Complete osseointegration was simulated using bonded contact conditions. A mesh convergence test was performed, and mesh refinement continued until the change in peak von Mises stress between successive mesh refinements was <5%. A static vertical load of 100 N was applied at the central occlusal fossa of the first molar under unilateral and bilateral loading conditions. Stress distribution was evaluated qualitatively and quantitatively using von Mises stress analysis. Statistical Analysis Used: No statistical analysis was performed. Stress distribution was compared descriptively using qualitative stress distribution patterns and quantitative von Mises stress values generated by the finite element models. Results: Under unilateral loading, stresses were concentrated predominantly on the working side, with the implant neck serving as the principal site of stress concentration. Increasing attachment height increased stress magnitudes in both bar and ball attachment systems under unilateral and bilateral loading conditions. Overall, stress concentrations were greatest at the implant neck, followed by the implant body and apical region. Cortical bone consistently exhibited higher stress values than cancellous bone across all models. Conclusion: Within the limitations of this finite element study, attachment height and splinting configuration influenced peri-implant stress distribution. Increased attachment height was associated with greater stress magnitudes in both attachment systems.
Within the limitations of the finite element model, both the presence and location of a nonrigid connector influenced stress distribution in a 5-unit FPD supported by a pier abutment.
P. Jain, A. Gupta, Karan Jarkani et al.· European Journal of Prosthod...· 0 citations
Objective. To evaluate the stress-strain state of bone tissue supported by six dental implants under various types of occlusal loading by finite element analysis.
Materials and methods. A three-dimensional finite element model of the mandibular segment with six implants and a fixed bridge prosthesis was developed. The...
S. Serebryanyy, A. Muraev, K. Salekh et al.· Perm Medical Journal· 0 citations
Background/Objectives: The biomechanical response of posterior single crowns is influenced by restorative stiffness, device geometry, loading direction, and bone architecture. This study evaluated the effect of crown material on stress distribution in posterior single crowns supported by the Bioxide-S Symbionic Tooth (...
V. Ronsivalle, Paola Lo Giudice, Magnus Persson et al.· Prosthesis· 0 citations
Abstract Background Removable partial dentures (RPDs) held in place by clasps have become a favored option for treating patients with partial tooth loss. However, these dentures have their drawbacks, including the issue of frequent displacement, which can lead to patient dissatisfaction and decreased usage, especially...
S. Agarwal, Subhabrata Maiti, J. Paulraj et al.· European Journal of General...· 0 citations
Aim: Finite element analysis (FEA) is widely used in implant prosthodontics to assess biomechanical behavior and support treatment planning in complex edentulous cases. This work aimed to evaluate stress distribution patterns associated with three implant configurations (all-on-four, all-on-six, and quad-zygomatic) in...
S. Latrèche, Olina Rios, F. Afota et al.· The Journal of Indian Prosth...· 0 citations
Background: This study aimed to evaluate the effects of three different biomaterials (MTA, Biodentine, BioAggregate) and two base thicknesses (2 mm, 3 mm) on stress distribution in a mandibular second primary molar model treated with pulpotomy using finite element analysis. Methods: A sound mandibular second primary mo...