Within the limitations of the finite element model, both the presence and location of a nonrigid connector influenced stress distribution in a 5-unit FPD supported by a pier abutment.
Abstract
Statement of problem: Fixed partial dentures (FPDs) involving an intermediate
pier abutment may be subjected to unfavorable biomechanical forces because of
the differential movement of the supporting abutment teeth. The design and
location of a nonrigid connector may influence the manner in which occlusal
stresses are transferred through the prosthesis and supporting structures.
Purpose: The purpose of this study was to evaluate the effect of rigid and
nonrigid connector designs on stress distribution in a 5-unit FPD with an
intermediate pier abutment using three-dimensional finite element analysis
(FEA).
Material and methods: A three-dimensional finite element model representing
a 5-unit metal-ceramic FPD was developed using SAP2000 software (Computers
& Structures, Inc.). The mandibular canine, second premolar, and second molar
were modeled as abutment teeth, with the periodontal ligament (PDL) and
surrounding cortical and trabecular bone incorporated into the model. Five
prosthetic configurations were evaluated: 1 rigid design and 4 nonrigid designs,
with the nonrigid connector positioned at the mesial aspect of the second molar,
distal aspect of the second premolar, mesial aspect of the second premolar, or
distal aspect of the canine. A static vertical occlusal load of 50 N was applied to
the cusp regions. Three loading conditions were simulated: simultaneous loading
of all abutment teeth to represent maximum centric occlusal contact, isolated
loading of the canine to simulate an anterior contact, and isolated loading of the
second molar to simulate a posterior contact. Stress distribution was evaluated
according to von Mises stress criteria.
Results: For all prosthetic designs and loading conditions, the highest stress
concentrations occurred in the regions subjected to loading, with maximum
values of approximately 2 MPa. Additional stress concentrations were observed
at the connector regions and cervical areas of the abutment teeth, particularly
around the pier abutment. Stress concentrations were also identified along the
root surfaces and at the apical regions of the abutments. Among the nonrigid
configurations, placement of the connector at the distal aspect of the second
premolar reduced the area of maximum stress concentration around the pier
abutment, particularly under isolated anterior and posterior loading conditions.
Conclusions: Within the limitations of the finite element model, both the
presence and location of a nonrigid connector influenced stress distribution in a
5-unit FPD supported by a pier abutment. Placement of the nonrigid connector
at the distal aspect of the second premolar resulted in a more favorable stress
distribution around the pier abutment than the other connector configurations
evaluated.
Clinical implications: The location of a nonrigid connector may be an important
consideration when designing an FPD involving an intermediate pier abutment,
particularly when the objective is to reduce localized stress concentration around
the pier abutment.
Abstract Background Removable partial dentures (RPDs) held in place by clasps have become a favored option for treating patients with partial tooth loss. However, these dentures have their drawbacks, including the issue of frequent displacement, which can lead to patient dissatisfaction and decreased usage, especially...
S. Agarwal, Subhabrata Maiti, J. Paulraj et al.· European Journal of General...· 0 citations
Aim: Finite element analysis (FEA) is widely used in implant prosthodontics to assess biomechanical behavior and support treatment planning in complex edentulous cases. This work aimed to evaluate stress distribution patterns associated with three implant configurations (all-on-four, all-on-six, and quad-zygomatic) in...
S. Latrèche, Olina Rios, F. Afota et al.· The Journal of Indian Prosth...· 0 citations
Background/Objectives: The biomechanical response of posterior single crowns is influenced by restorative stiffness, device geometry, loading direction, and bone architecture. This study evaluated the effect of crown material on stress distribution in posterior single crowns supported by the Bioxide-S Symbionic Tooth (...
V. Ronsivalle, Paola Lo Giudice, Magnus Persson et al.· Prosthesis· 0 citations
Purpose:Polyether ether ketone (PEEK), a recently introduced material claiming to absorb stress, has been assessed in limited studies for use in tooth-implant-supported fixed partial dentures (FPDs). This study aims to evaluate the effect of prosthetic material on stress accumulation in the teeth, periodontal tissues,...
Samet Tekin, Ayşe Rençber Kızılkaya· Türk Doğa ve Fen Dergisi· 0 citations
Within the limitations of this finite element study, attachment height and splinting configuration influenced peri-implant stress distribution, and increased attachment height was associated with greater stress magnitudes in both attachment systems.
Hari Narayan Singla, Reeta Jain, Rupandeep Kaur Samra et al.· The Journal of Indian Prosth...· 0 citations
Denture base elastic-property assignment may influence how mechanical stress is distributed between a complete denture and its supporting tissues. This study compared rigid and flexible denture base material conditions in an idealized maxillomandibular finite element (FE) model at the final static bilateral clenching s...
J. Seo, Jeong-Hyeon Lee, Won-Gi Kim et al.· Materials· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.