The two analyzer–reagent systems showed positive analytical associations, but the magnitude and dispersion of paired differences varied by assay, but the magnitude and dispersion of paired differences varied by assay.
Abstract
Background/Objectives: Prothrombin time (PT), international normalized ratio (INR), and activated partial thromboplastin time (aPTT) are routinely used coagulation assays, and analyzer–reagent differences may affect result comparability. This study evaluated analytical comparability between the Sysmex CS-2500 System using Siemens reagents and the Tokra Medical NOVAE II for PT, INR, and aPTT. Methods: Residual routine citrated plasma specimens were measured on both systems. The CS-2500 was designated as the comparator system. Passing–Bablok regression and Bland–Altman analysis were used as the primary method-comparison approaches; Pearson and Spearman correlations and exploratory categorical agreement were secondary analyses. Results: Fifty paired measurements were analyzed for PT and INR and 54 for aPTT. For all three parameters, the 95% confidence interval (CI) for the Passing–Bablok intercept included 0 and the 95% CI for the slope included 1, providing no statistically supported evidence of constant or proportional bias by regression. Mean paired differences (NOVAE II minus CS-2500) were +1.27 s for PT, +0.023 for INR, and +2.32 s for aPTT. The 95% limits of agreement were −0.15 to +2.69 s for PT, −0.112 to +0.159 for INR, and −1.70 to +6.33 s for aPTT. Categorical agreement was influenced by analyzer-specific reference intervals and by the low prevalence of abnormal results. Conclusions: The two analyzer–reagent systems showed positive analytical associations, but the magnitude and dispersion of paired differences varied by assay. Because no clinical equivalence margins were prespecified and markedly pathological or therapeutic-range samples were sparsely represented, these findings support analytical comparison and local verification but do not establish clinical interchangeability.
These locally derived RIs may improve the interpretation of FXII and ATIII results and reduce unnecessary follow-up testing caused by inappropriate generic intervals and highlight the importance of local RI verification when applying manufacturer-derived intervals or changing analytical platforms.
Yanyan Xia, Gui-Ting Zhang, Hong Zhu et al.· JIM - Journal of Immunologic...· 0 citations
Background and Objective: D-dimer results differ across analytical platforms, which may affect their clinical interpretation. This study aimed to compare the analytical agreement and threshold-based classification of three routinely used D-dimer analyzers. Methods: Of 150 consecutive residual citrated plasma specimens,...
Bağnu Dündar, Betül Özbek Kurtul, B. Badilli et al.· Diagnostics· 0 citations
The performance of the Horiba Microsemi analyzer operated by clinical staff in the emergency department of V. Buzzi Children’s Hospital compared with laboratory testing was evaluated, and strong correlation between POCT (capillary and venous) and laboratory measurements was observed.
Giancarlo Lai, Antonio Torchia, G. Aiello et al.· European Journal of Pediatri...· 0 citations
INTRODUCTION
It is recommended to detect lupus anticoagulant (LA) using two phospholipid-dependent clotting assays, including a LA-sensitive activated partial-thromboplastin-time (aPTT). Among these reagents, Staclot-LA assay is performed on a mixture of test and normal plasma with and without hexagonal phase phospholi...
V. Siguret, G. Jourdi, S. Melicine et al.· International Journal of Lab...· 0 citations
Interpretation of pediatric coagulation results depends on the reference interval (RI) applied, yet the extent to which RI source affects result classification is rarely quantified. This retrospective single-center study determined how RI source affects out-of-RI flagging in pediatric coagulation testing. Analyzer-spec...
Tuba Çakmak Ercan, D. Topcu, G. Bozkaya· Clinica chimica acta; intern...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.