The feasibility and reproducibility of adapting the T2‐Relaxation‐Under‐Spin‐Tagging (TRUST) MRI sequence for noninvasive measurement of venous oxygenation in the upper arm were investigated, aiming to enable future in vivo validation of T2b‐oxygenation calibration curves in sickle cell disease (SCD).

Read PDF

Similar papers

Open access Sep 2026

Multi‐angle fluoroscopic lung perfusion imaging using x‐ray pulsatility index: A pilot study in healthy subjects

Multi‐angle XPI fluoroscopy enables non‐invasive regional lung perfusion assessment with low radiation exposure and provides preliminary reference values for future clinical investigation.

Matthew Smith, B. W. Richmond, Savannah Gregory et al. · 0 citations
Open access Sep 2026

Implementation and validation of a clinically compatible four-shell diffusion MRI protocol for ischemic stroke research

Highlights • Provides complete acquisition parameters, quality control procedures, and processing scripts to facilitate implementation of advanced multi-shell diffusion imaging in clinical stroke research settings.• Evaluation in twelve healthy volunteers, including a test-retest reliability assessment in six participa...

Emmanuelle Gourieux, J. Pietras, A. Delphin et al. · 0 citations
Open access Aug 2026

Multi‐Vendor and Multi‐Site Characterization of 13C Coils for Clinical Studies

A gradient-recalled echo (GRE) sequence is presented alongside an image-based analysis for SNR estimation and QC of 13C coils, advancing the clinical translation of 13C MRS methodologies.

Emil S Christensen, Andreas Clemmensen, E. S. Hansen et al. · 0 citations
Open access Sep 2026

Feasibility of Spin‐ and Gradient‐Echo Dynamic Susceptibility Contrast MRI for Microvascular Characterization at 7 Tesla

Perfusion MRI, especially dynamic susceptibility contrast (DSC), is vital for glioma diagnosis and monitoring. While gradient‐echo DSC is the current recommended implementation, combined spin‐ and gradient‐echo (SAGE) DSC additionally allows for vessel size imaging (VSI) and has shown feasibility for microvascular char...

Karen N. van der Werff, D. van Dorth, Krishnapriya Venugopal et al. · 0 citations
Aug 2026

Advanced Inversion Recovery Single Point Imaging for High Spatial Resolution and Quantitative Oxygen Imaging

The partial pressure of oxygen (pO2) in tissue is a tightly regulated physiological quantity. Hypoxia is a hallmark of many diseases, and changes in tissue pO2 underline critical developmental, metabolic, and physiological processes. Electron paramagnetic resonance oxygen imaging (EPROI) has emerged as the most precise...

Boris Epel, Irene Canavesi, Mrignayani Kotecha · 0 citations