2026· IEEE Transactions on Instrumentation and Measurement· Vol 75, pp. 9006416-9006416· 0 citations· 26 references
Abstract
Metal oxide surge arresters (MOAs) are core overvoltage protection devices in power systems. However, conventional single-parameter MOA fault diagnostic methods exhibit low accuracy and limited anti-interference capability in complex operating conditions. In this article, a distributed in situ measurement technique and a lightweight analytical criterion for MOA fault diagnosis are proposed. First, a measurement system is designed based on a distributed parameter equivalent circuit model, which deploys eight embedded sensors within the valve column along the axial direction. This architecture enables synchronous acquisition of the longitudinal leakage current vector and temperature profile. Second, experiments are performed under three typical conditions of normal operation, surface fouling, and valve disk failure to reveal the distribution characteristics of temperature and leakage current. Third, an analytical criterion is proposed, which integrates multiple feature parameters, including leakage current inhomogeneity coefficient, full current, and maximum temperature rise. Last, the K-means clustering method is adopted to determine thresholds for three typical operating conditions. The experimental results show that the proposed criterion achieves an accuracy of 96.67 %, outperforming single-feature and traditional machine learning methods. The research provides a new approach for MOA fault diagnosis.
The Metal-Oxide Arrester (MOA) is a crucial device for ensuring the safety of power grids, but its fault diagnosis faces the challenge of scarce actual fault samples. In this study, a 3D electro-thermal coupled simulation model is developed to reconstruct four operating conditions: internal moisture, aging of the insul...
When a short-circuit fault occurs along the transmission line of a modular multilevel converter high-voltage direct-current (MMC-HVDC) grid, the sub-module capacitors discharge, causing the fault current to rapidly rise, posing a threat to the safe operation of the system. Therefore, this paper proposes a novel fault l...
Xiangyang Liu, Zhong Tang, Hong Qian et al.· Energies· 0 citations
In practical power systems, transformers are continuously involved in voltage conversion and electrical-energy transmission, so once abnormal operating conditions appear inside the equipment, the influence may gradually spread to the stability of the entire grid. Because early-stage transformer faults are usually weak...
Rui Zhu· Applied and Computational En...· 0 citations
In this paper, a fault diagnosis method based on temperature rise detection is proposed for power converters in switched reluctance motor drive systems used in electrical transportation equipment. First, the total power losses of all power devices are calculated and recorded under different operating conditions in both...
Xiang-Su Wang, Zhijie Zhang, Qing Wang et al.· Machines· 0 citations
Electronic devices and power systems are vulnerable to transient overvoltage caused by lightning strikes, switching operations, and system faults. In DC circuit breaker applications, metal oxide surge arresters (MOSAs), composed of multiple metal oxide varistors (MOVs), play a critical role in absorbing fault energy an...
Jeong-Cheol Lee, I. Kwon, Y. Kwak et al.· Electrical Insulation Confer...· 0 citations
As core connection components in power transmission systems, high-voltage bushings operate under extreme conditions for extended periods, including high voltage, high current, elevated ambient temperature, and intense mechanical loads. Under the combined effects of electrical, thermal, and mechanical stresses, internal...
Guang-Ning Wu, Shengbing Wei, Zhipeng Shi et al.· IEEE Transactions on Instrum...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.