Skip to content
Open access

Technical evaluation of retrofitting solid-state transformers and battery energy storage systems for peak shaving within the footprint of ageing line-frequency distribution transformers in Aotearoa New Zealand

Sep 2026 · Archives of Sustainable Energy Systems · 0 citations · 72 references

Abstract

Aotearoa New Zealand’s distribution network faces significant strain from a 250% increase in distributed solar photovoltaic installations between 2013 and 2022. These trends increase vulnerability to failure of line-frequency transformers (LFT). The objective of this paper is to investigate the technical feasibility of retrofitting existing LFT footprints with integrated solid-state transformers (SST) with battery energy storage systems (BESS).  Using MATLAB/Simulink to simulate an 11 kV radial feeder, the study evaluated performance under strenuous dual-peak winter demand periods with transformers loaded to 110% of their rated capacity. The research demonstrates the potential recovery of up to 80% of the physical volume compared to LFTs allowing the footprint to be repurposed for decentralised BESS. The findings indicate that the medium density storage technologies (0.15-0.35 kWh/L) are the best option. The technology enables  a load curtailment of 20% reducing the transformer loading from 110% down to the safe 90% threshold. However, the dual-peak demand profile for Aotearoa New Zealand’s often depletes storage during morning cycles, while restricted charging windows limites utilisation of higher-density storage. Furthermore, while successful at the 0.4 kV busbar level, the aggregate impact of the main 11 kV feeder remaines minimal below 7.6%. It is recommended that future research focus on predictive control methods to optimise storage state of charge across successive peaks and the integration of downstream renewables to expand charging windows.

Read PDF

Similar papers

Open access Sep 2026

Reduce stress on local distribution transformers through load, battery control, and photovoltaics: A Wellington case study

The growth of electric vehicles (EVs) and photovoltaic (PV) generation introduces new operational challenges for low voltage (LV) distribution networks, including transformer overloading, voltage deviations and bidirectional power flows. Mitigation measures often include the upgrading of conventional transformers and t...

Kittiphonh Phengthavongsa, Daniel Burmester · 0 citations
Open access Aug 2026

Cross-Class Value of Battery Energy Storage in Low-Voltage Grids: Grid Relief, Dispatch-Coupled Ageing, and Cost-Effectiveness

The German low-voltage (LV) distribution grid faces stress from the build-out of distributed photovoltaic (PV) units. Battery storage is widely proposed as a solution, yet the literature is partitioned by storage scale, placement, and how ageing is treated. This study introduces a unified cross-class assessment of the...

Sebastian Zurmühlen, Jonas Brucksch, D. U. Sauer · 0 citations
Open access Sep 2026

Modelling a fixed-speed pumped hydro storage system for reactive power management in power grids with high penetration of inverter-based resources: A case study of Aotearoa New Zealand

The increasing penetration of inverter-based renewable energy resources (IBRs) presents significant challenges to power system voltage stability and reactive power management due to the declining contribution of conventional synchronous generation. This study investigates the reactive power support capability of a fixe...

Balasree Muraleedharan, Daniel Burmester · 0 citations
Open access Sep 2026

Co‐Optimisation of Battery Energy Storage Systems for Voltage Regulation and Reverse Power Flow Control in PV‐Enriched Low Voltage Distribution Network

High photovoltaic (PV) penetration in low‐voltage (LV) radial feeders often causes midday voltage rise and upstream reverse power flow (RPF), constraining further PV integration without local flexibility. In this paper, distributed battery energy storage systems (BESS) are investigated as a practical flexibility reso...

Nirakar Nepal, Raagini Upadhyay, Samvid Neupane et al. · 0 citations
Review Open access Sep 2026

EXPERIMENTAL QUANTIFICATION AND TECHNO-ECONOMIC IMPACT OF LOAD UNBALANCE ON LOW-VOLTAGE DISTRIBUTION TRANSFORMERS: A CASE STUDY OF MBANZA-NGUNGU, DEMOCRATIC REPUBLIC OF THE CONGO

Load unbalance in low-voltage (LV) distribution networks is a major cause of transformer degradation and technical losses, yet it remains under-documented in Sub-Saharan Africa. This study presents an experimental quantification of load unbalance on three 630 kVA distribution transformers (Yukula, Offitra, and Hôpital)...

Malungila Hardy, Basiemi Ngitukulu Winnie, Iyolo Pongo Rodolphe · 0 citations
Open access Aug 2026

Comparative analysis of steady-state and dynamic models for grid-connected photovoltaic farm performance monitoring: A case study of Huawei SUN2000-60KTL-M0 inverter

This study evaluates the solar-to-electrical energy conversion performance of a 63.24 kWp grid-connected photovoltaic (PV) farm equipped with a Huawei SUN2000-60KTL-M0 (60 kW) inverter by comparing a steady-state diagnostic model against a dynamic observability assessment. A single-instant snapshot of 12 PV strings on...

Dias Prihatmoko, R. Asnawi, Moh. Khairudin et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.