A feasibility study based on a 2.5D U-Net architecture to detect GME in space-time connected data, resulting in improved detection of moving GMEs against the background with respect to classical spot detection algorithms and 2D U-Net, yet retaining real-time execution speed with respect to more complex deep-learning architectures is proposed.
Abstract
Gaseous microemboli (GME) represent a common complication of cardiac structural interventions across both surgical and transcatheter approaches. Intraoperative transesophageal echocardiography (TEE) represents a convenient methodology to monitor and visualize the presence of circulating GME. However, their detection and quantification are far from trivial due to operator-dependent view, high velocity, and objects with similar structure in the background. Here, we propose a feasibility study based on a 2.5D U-Net architecture to detect GME in space-time connected data. We applied and tested such an architecture on a pilot dataset of eight TEE recordings ($60$ fps, $600\times 800$ pixels) from eight different patients undergoing cardiac surgery, resulting in improved detection of moving GMEs against the background with respect to classical spot detection algorithms and 2D U-Net, yet retaining real-time execution speed with respect to more complex deep-learning architectures. Under leave-one-patient-out cross-validation, the selected model achieved strong detection performance under a three-pixel radius-tolerant grace-zone evaluation, with a precision of 92.55\% and recall of 80.54\%, corresponding to radius-tolerant Intersection over Union (IoU) and Dice coefficients of 73.95\% and 84.13\%, respectively. Complementarily, strict pixel-based segmentation metrics were also computed, yielding an IoU of 41.74\% and a Dice coefficient of 57.98\%. The selected model achieved an average inference time of $0.12 s$ per batch on the tested hardware. To assess specificity on unseen data, we additionally evaluated the model on an external GME-negative TEE dataset, where it produced predominantly empty or near-empty masks, indicating a low rate of spurious detections. These results support the technical feasibility of real-time GME segmentation.
Volumetric real-time MRI is feasible for the guidance of invasive procedures such as right-heart catheterization at 0.55T and offers flexible real-time re-slicing, volumetric 3D visualization, and the potential for improved device monitoring.
Prakash Kumar, R. Ramasawmy, A. Javed et al.· Journal of Cardiovascular Ma...· 0 citations
Peripheral Artery Disease (PAD) is a serious and potentially limb and life-threatening condition that demands a timely and accurate diagnosis to prevent severe complications. Traditional diagnostic methods are often slow and error prone. Although PAD localization remains relatively less explored using machine learning,...
Md Raisul Islam, M. Zaman, S. Ahmmed et al.· International Conference on...· 0 citations
The substantially lower subject-disjoint performance of TriFusion-PCGNet indicates that the record-level results should not be interpreted as evidence of patient-independent generalization, and further validation on independent subject-annotated datasets is required.
Tolga Çakmak, Ç. Mirzaoğlu, Melike Demir et al.· Life· 0 citations
The feasibility of the proposed Echo-EU-Net-based method in automatically segmenting the left ventricle and measuring EF in TSV TEE has been demonstrated and may shed light on lightweight deep learning-based fully automated left ventricular segmentation and EF quantification in TSV TEE.
Yijun Ling, Yuan Tian, W. Qin et al.· Ultrasound in Medicine and B...· 0 citations
BACKGROUND
Accurate assessment of left ventricular outflow tract (LVOT) gradients is critical for hypertrophic cardiomyopathy management, yet Doppler-based measurements are technically demanding and require expertise. The objective of this work was to develop a multi-view deep learning model capable of classifying LVOT...
O. Crystal, J. Farina, I. Scalia et al.· Circulation Cardiovascular I...· 0 citations
This document addresses the needs for an "ideal" post-processing software for 4D flow in patients with CHD and provides information on general requirements, velocity encoding, offset and aliasing correction, visualization, segmentation and reconstruction as well as output data.
Julio Garcia, J. Geiger, Adam B. Christopher et al.· Journal of Cardiovascular Ma...· 0 citations
Related blog posts
MIT News · Artificial Intelligence· news.mit.eduOct 13, 2026
Machine-learning networks can learn without detailed instructions from a designer. Those that do may offer insight into how the brain reorganizes itself during learning.
MIT News · Artificial Intelligence· news.mit.eduSep 29, 2026
Professor Sherry Turkle’s new book, “Artificial Intimacy,” offers a withering critique of chatbots and the antisocial dynamics she believes they encourage.