A feasibility study based on a 2.5D U-Net architecture to detect GME in space-time connected data, resulting in improved detection of moving GMEs against the background with respect to classical spot detection algorithms and 2D U-Net, yet retaining real-time execution speed with respect to more complex deep-learning architectures is proposed.

Abstract

Gaseous microemboli (GME) represent a common complication of cardiac structural interventions across both surgical and transcatheter approaches. Intraoperative transesophageal echocardiography (TEE) represents a convenient methodology to monitor and visualize the presence of circulating GME. However, their detection and quantification are far from trivial due to operator-dependent view, high velocity, and objects with similar structure in the background. Here, we propose a feasibility study based on a 2.5D U-Net architecture to detect GME in space-time connected data. We applied and tested such an architecture on a pilot dataset of eight TEE recordings ($60$ fps, $600\times 800$ pixels) from eight different patients undergoing cardiac surgery, resulting in improved detection of moving GMEs against the background with respect to classical spot detection algorithms and 2D U-Net, yet retaining real-time execution speed with respect to more complex deep-learning architectures. Under leave-one-patient-out cross-validation, the selected model achieved strong detection performance under a three-pixel radius-tolerant grace-zone evaluation, with a precision of 92.55\% and recall of 80.54\%, corresponding to radius-tolerant Intersection over Union (IoU) and Dice coefficients of 73.95\% and 84.13\%, respectively. Complementarily, strict pixel-based segmentation metrics were also computed, yielding an IoU of 41.74\% and a Dice coefficient of 57.98\%. The selected model achieved an average inference time of $0.12 s$ per batch on the tested hardware. To assess specificity on unseen data, we additionally evaluated the model on an external GME-negative TEE dataset, where it produced predominantly empty or near-empty masks, indicating a low rate of spurious detections. These results support the technical feasibility of real-time GME segmentation.

View source

Similar papers

Open access Aug 2026

Volumetric real-time MRI for the guidance of cardiac catheterization at 0.55T.

Volumetric real-time MRI is feasible for the guidance of invasive procedures such as right-heart catheterization at 0.55T and offers flexible real-time re-slicing, volumetric 3D visualization, and the potential for improved device monitoring.

Prakash Kumar, R. Ramasawmy, A. Javed et al. · 0 citations
Conference Jul 2026

PAD-Net: Towards Intelligent Diagnosis of Peripheral Artery Disease with a Deep Learning Framework

Peripheral Artery Disease (PAD) is a serious and potentially limb and life-threatening condition that demands a timely and accurate diagnosis to prevent severe complications. Traditional diagnostic methods are often slow and error prone. Although PAD localization remains relatively less explored using machine learning,...

Md Raisul Islam, M. Zaman, S. Ahmmed et al. · 0 citations
Open access Aug 2026

TriFusion-PCGNet: A Hybrid Multi-Branch Deep Learning Network for Energy-Aware Normal/Abnormal Heart Sound Classification

The substantially lower subject-disjoint performance of TriFusion-PCGNet indicates that the record-level results should not be interpreted as evidence of patient-independent generalization, and further validation on independent subject-annotated datasets is required.

Tolga Çakmak, Ç. Mirzaoğlu, Melike Demir et al. · 0 citations
Aug 2026

Echo-EU-Net: Lightweight Deep Learning for Fully Automated Left Ventricular Segmentation and Ejection Fraction Quantification in Transgastric Short-Axis View on Transesophageal Echocardiography.

The feasibility of the proposed Echo-EU-Net-based method in automatically segmenting the left ventricle and measuring EF in TSV TEE has been demonstrated and may shed light on lightweight deep learning-based fully automated left ventricular segmentation and EF quantification in TSV TEE.

Yijun Ling, Yuan Tian, W. Qin et al. · 0 citations
Aug 2026

Beyond Doppler: Scalable AI Detection of LVOT Obstruction in HCM.

BACKGROUND Accurate assessment of left ventricular outflow tract (LVOT) gradients is critical for hypertrophic cardiomyopathy management, yet Doppler-based measurements are technically demanding and require expertise. The objective of this work was to develop a multi-view deep learning model capable of classifying LVOT...

O. Crystal, J. Farina, I. Scalia et al. · 0 citations
Open access Aug 2026

4D flow cardiac magnetic resonance postprocessing in congenital heart disease: SCMR FLIICR workgroup recommendations.

This document addresses the needs for an "ideal" post-processing software for 4D flow in patients with CHD and provides information on general requirements, velocity encoding, offset and aliasing correction, visualization, segmentation and reconstruction as well as output data.

Julio Garcia, J. Geiger, Adam B. Christopher et al. · 0 citations

Related blog posts

MIT News · Artificial Intelligence Sep 29, 2026

Who we become when we talk to machines

Professor Sherry Turkle’s new book, “Artificial Intimacy,” offers a withering critique of chatbots and the antisocial dynamics she believes they encourage.

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.