Aug 2026· Magnetic Resonance in Medicine· Vol 96, pp. 2240 - 2252· 0 citations· 44 references
Medicine
Abstract
To evaluate single‐ and dual‐band pulse modules for suppressing extra‐cardiac signal in cardiac MRI, and test their applicability for time‐efficient imaging with reduced FOV in myocardial T2 mapping at 3 T.
To extend localized quadratic (LQ) RF encoded spin‐echo imaging with acquisition and reconstruction strategies that improve efficiency and artifact robustness, positioning it as a practical alternative to 3D FSE for high‐resolution volumetric brain MRI.
Guruprasad Krishnamoorthy, J. Velikina, James G Pipe· Magnetic Resonance in Medici...· 0 citations
A gradient-recalled echo (GRE) sequence is presented alongside an image-based analysis for SNR estimation and QC of 13C coils, advancing the clinical translation of 13C MRS methodologies.
Emil S Christensen, Andreas Clemmensen, E. S. Hansen et al.· Magnetic Resonance in Medici...· 0 citations
Perfusion MRI, especially dynamic susceptibility contrast (DSC), is vital for glioma diagnosis and monitoring. While gradient‐echo DSC is the current recommended implementation, combined spin‐ and gradient‐echo (SAGE) DSC additionally allows for vessel size imaging (VSI) and has shown feasibility for microvascular char...
Karen N. van der Werff, D. van Dorth, Krishnapriya Venugopal et al.· NMR in Biomedicine· 0 citations
The feasibility and reproducibility of adapting the T2‐Relaxation‐Under‐Spin‐Tagging (TRUST) MRI sequence for noninvasive measurement of venous oxygenation in the upper arm were investigated, aiming to enable future in vivo validation of T2b‐oxygenation calibration curves in sickle cell disease (SCD).
J. Fernandes, K. Baas, M. Caan et al.· Magnetic Resonance in Medici...· 0 citations
The aim of this work is to investigate if q‐space trajectory imaging (QTI) waveforms can be designed to probe QTI metrics at a single centroid frequency under realistic experimental conditions for in vivo human brain imaging.
Svenja Niesen, Marten Veldmann, Ali Ajouz et al.· Magnetic Resonance in Medici...· 0 citations
Abstract Cardiac arrhythmias are one of the world’s leading causes of death. Non-invasive magneto-anatomical mapping aims to identify arrhythmogenic regions based on external magnetic sensors. An alternating two-stage state estimation and parameter optimization scheme has proven promising for cardiac current density es...
Lukas Elsner, H. Eikens, Sören Lange et al.· Current Directions in Biomed...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.