Skip to content

Change Point--Aware Evaluation and Re-Calibration of PPG-Based Blood Pressure Estimation

Aug 2026 · 0 citations · 34 references
Engineering Computer Science

TL;DR

This work proposes a fluctuation-aware evaluation framework for PPG-based BP estimation based on time-series change point detection and introduces a targeted re-calibration framework triggered by detected BP change points, improving robustness without modifying model architectures.

Abstract

Non-invasive continuous blood pressure (BP) monitoring using photoplethysmography (PPG) is a promising alternative to cuff-based measurements. However, existing PPG-based BP estimation studies predominantly rely on aggregated performance metrics (e.g., mean absolute error) computed over entire evaluation intervals, which can obscure model failures during rapid BP fluctuations and limit clinical relevance. In this work, we propose a fluctuation-aware evaluation framework for PPG-based BP estimation based on time-series change point detection. Instead of heuristic BP thresholding (e.g., $\Delta\mathrm{BP}>10\mathrm{mmHg}$), we identify BP change points by capturing abrupt distributional shifts in BP trajectories and evaluate estimation performance specifically during these fluctuation periods. Our analysis shows that several state-of-the-art models exhibit substantial performance degradation around BP change points, and that periodic test-time calibration is insufficient to handle such dynamic BP variations. To address this limitation, we introduce a targeted re-calibration framework triggered by detected BP change points, improving robustness without modifying model architectures. To the best of our knowledge, this is the first systematic evaluation of PPG-based BP estimation from a BP change point perspective, highlighting the importance of fluctuation-aware evaluation and calibration for real-world continuous BP monitoring.

View source

Similar papers

Preprint Aug 2026

Reassessing the Feasibility of PPG-Based Non-Invasive Blood Glucose Level Estimation

Non-invasive blood glucose level (BGL) estimation from photoplethysmography (PPG) holds great promise for wearable health monitoring, but results across studies are hard to compare due to inconsistent datasets, data leakage, and non-standardized evaluation metrics. We present the first reproducible, extensible evaluati...

Supraja Ramesh, Markus Neufeld, Michael Küttner et al. · 0 citations
Preprint Aug 2026

Calibration-Free Cuffless Blood Pressure Estimation Using Multimodal ECG-PPG Fusion on a Google Pixel Watch

The feasibility of consumer-grade smartwatches as accessible platforms for deploying robust BP estimation algorithms is highlighted, though clinical reliability will require larger, more diverse populations and additional sensing modalities.

Jathushan Kaetheeswaran, Bo-Yi Ma, Ali Abedi et al. · 0 citations
Open access Jul 2026

Personalized Calibration and Hybrid Feature Fusion for Continuous Blood Pressure Estimation Using PPG and ECG Signals

Comparative and ablation results indicate improved baseline performance in the current experimental setting, suggesting the methodological feasibility of the proposed framework for small-sample continuous BP estimation, and shows potential for wearable BP monitoring.

Zichuan Zhang, Peng Qu, Hong Tang · 0 citations
Preprint Jul 2026

Low-Rate Wrist SpO2 Estimation under Micro-Perturbations Using Motion-Aware Beat Selection and Perfusion-Guided Calibration

A lightweight low-rate wrist SPO2 estimation framework that integrates motion-aware beat selection and perfusion-guided calibration is proposed that achieves the best 25 Hz performance and reduces PPG sensor power consumption for energy-efficient wearable implementation.

Zequan Liang, Ning Miao, Wei Shao et al. · 0 citations
Sep 2026

Compact PPG-Based Blood Pressure Estimation Using Hardware-Efficient Knowledge Distillation

Continuous blood pressure (BP) monitoring from photoplethysmography (PPG) is compelling for wearable health applications, yet deep learning models for cuffless BP estimation are rarely evaluated under edge-deployment constraints. We propose a hardware-oriented knowledge distillation framework for compact PPG-only BP es...

N. J. Limbaga, Osama Amin, Basem Shihada et al. · 0 citations

Related blog posts

MIT News · Artificial Intelligence Sep 29, 2026

Who we become when we talk to machines

Professor Sherry Turkle’s new book, “Artificial Intimacy,” offers a withering critique of chatbots and the antisocial dynamics she believes they encourage.

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.