REM test dataset: reference and tuned luminous intensity distributions (EULUMDAT) with photometric plots and lighting situations setup
Abstract
The dataset is organized in four top-level directories: ldt, which contains the luminous intensity distributions in the EULUMDAT format; plots, which contains their graphical representations together with the resulting photometric maps of the lighting situations; and xlsx_in and xlsx_out, which contain the parameters of the lighting situations and the photometric results before and after tuning, respectively. The directory tree is shown below. proj_data/ ldt/ reference_ldt/ 649 original LDT files tuned_R11_deg_ldt/ 31,800 tuned LDT files plots/ I(C, gamma) plots/ 31,800 PNG files Lighting stuations C - Eh plots/ 412 PNG files Lighting stuations M - L plots/ 31,388 PNG files xlsx_in/ Test_data_C_series.xlsx 412 C-class situations Test_data_M_series.xlsx 31,526 M-class situations xlsx_out/ Sit_C_series_R11_output.xlsx 412 C-class situations Sit_M_series_R11_output.xlsx 31,526 M-class situations The contents of the individual directories are as follows. ldt/reference_ldt contains 649 original photometric files of the luminaires used in the test dataset, as provided by their manufacturers. These are the input distributions I(C,γ) to which REM was applied. ldt/tuned_R11_deg_ldt contains 31,800 modified photometric files obtained with REM for the angular support radius ρ = 11°. Each file corresponds to one lighting situation for which REM yielded a standard-compliant design: 412 files for C-class situations and 31,388 files for M-class situations. The files keep the EULUMDAT format and header of the original luminaire; only the luminous intensity matrix [Iij] and the symmetry indicator are modified. plots/I(C, gamma) plots contains, for each tuned file, a heatmap of the luminous intensity distribution plotted in Cartesian (C,γ) coordinates. Each image consists of three panels: the original distribution, which fails the Uo requirement (top); the tuned distribution (middle); and their difference (bottom), which shows the directions in which the distribution was modified: light colors mean an increase in I and dark colors a decrease. plots/Lighting situations C - Eh plots contains 412 heatmaps of the horizontal illuminance Eh over the calculation field for the C-class situations, computed with the original (top) and the tuned (bottom) distribution. plots/Lighting situations M - L plots contains 31,388 analogous heatmaps of the road-surface luminance L for the M-class situations: The heatmaps are arranged in the following order. For each successive observer (the number of observers equals the number of traffic lanes), the panels show: ?? the L heatmap for the original I(C,γ) distribution, ?? the L heatmap for the tuned I(C,γ) distribution. xlsx_in contains two MS Excel workbooks, Test_data_C_series.xlsx and Test_data_M_series.xlsx, with the input parameters of the 412 C-class and 31,526 M-class lighting situations for which LDT files are provided. These parameters suffice to reproduce the lighting calculations in DIALux-type software. xlsx_out contains two workbooks, Sit_C_series_R11_output.xlsx and Sit_M_series_R11_output.xlsx, with the results of REM for ρ = 11° for all 412 C-class and 31,526 M-class test situations. Each row corresponds to one situation, and its row number is the identifier <id> used in the file names (see below). Every installation and photometric parameter is given in two columns: the value for the original distribution (e.g., uo_l) and the value for the tuned distribution (suffix __OUT, e.g., uo_l__OUT). The <Initial/Output> bitmask columns hold the status bitmasks of the original and the tuned design, and iter_count gives the number of REM iterations. All files derived from a single lighting situation share a common name stem <luminaire>_[<series>]_R<ρ>__row_<id>, where <luminaire> identifies the luminaire and its optics, <series> ?? {C, M} is the lighting-class series, R<ρ> gives the angular radius ρ in degrees, and <id> is the identifier of the lighting situation in the test dataset (<id> starts from 2). The suffix __sit marks the illuminance and luminance maps of a situation. For example, the files VIA-M-OP3_SH_50W_3000K_[C]_R11__row_134.ldt, VIA-M-OP3_SH_50W_3000K_[C]_R11__row_134.png, VIA-M-OP3_SH_50W_3000K_[C]_R11__row_134__sit.png contain the tuned distribution, its heatmap, and the resulting Eh map of the same C-class situation.