Results indicate that the detector can provide reliable and reproducible data and demonstrate the applicability of active-matrix technology to experimental 3D dosimetry in radiotherapy.
Abstract
A three-dimensional electronic detector array proof-of-principle prototype based on active-matrix technology was developed for radiotherapy dosimetry. The system consists of a 30×30×15 cm3 PMMA phantom with 2645 embedded detector elements distributed in five active matrices at five depths. Percent depth-dose (PDD) and profile measurements for a 6 MV photon beam from different radiotherapy linacs were acquired and compared to GEANT 4 Monte Carlo simulations. Deviations were < 1% (MCDetector - modelled detector) and < 3% (MCPMMA - PMMA medium). Measurement versus simulation average difference was 0.5% (MCDetector) and 1.3% (MCPMMA) within the irradiated field. Reproducibility across measurements was 0.5%. These results indicate that the detector can provide reliable and reproducible data and demonstrate the applicability of active-matrix technology to experimental 3D dosimetry in radiotherapy.
An initial 3D electronic detector array prototype for radiotherapy, consisting of 2645 diodes (8.0 mm pitch), was modelled with Geant4 and MCNP6.2 Monte Carlo codes to simulate irradiations of 2×2, 3×3, 4×4, and 5×5 cm2 field sizes with a 6 MV photon beam. Comparisons with Treatment Planning Software (TPS) data reveale...
R. Ocampo, D. Roa, Enzo Aucca et al.· Journal of Physics, Conferen...· 0 citations
Accurate range verification is a critical component of proton therapy, ensuring that the high dose gradients characteristic of Bragg peaks are delivered precisely to the target volume. This work presents the first experimental evaluation of the easyPET.3D, a compact and cost-effective preclinical positron emission tomo...
A. C. M. Magalhães, P. Correia, M. Grossmann et al.· Biomedical engineering and p...· 0 citations
Objective. FLASH radiotherapy which employs an ultra-high dose rate (UHDR) ( >40 Gy s −1), effectively protects normal tissues and organs while maintaining robust tumor control. However, it also presents serious challenges for quality assurance (QA). Currently, dosimeters face various limitations under FLASH radiothera...
Wei Zhang, Chang Cheng, Rong-Hu Mao et al.· Physics in Medicine and Biol...· 0 citations
Despite its substantial weight and limited maximum field size, GRID-based SFRT offers straightforward treatment planning, efficient dose delivery, and the potential to enhance tumor control through its characteristic peak-to-valley dose distribution.
R. Yaparpalvi, D. Mynampati, M. Garg et al.· Medical Dosimetry· 0 citations
This study aims to verify the photon beam energy characteristics of an Elekta Synergy Platform LINAC at Kathmandu Cancer Center, Tathali Nala road by comparing measured PDD data with established British Journal of Radiology (BJR) Supplement 25 and other published literature. PDD measurements were performed for photon e...
Raja Prajapat, Junaid Abdul Salam, A. Adhikari et al.· Nepal Journal of Science and...· 0 citations
Advanced 3D dosimetry materials are essential for high-resolution measurement of dose distributions in radiotherapy. This study investigates a bone-mimicking 3D dosimeter, developed as part of a broader project on multiphase dosimeters replicating different human tissues. The dosimeter formulation was modified with mag...
M. Kozicki, M. Jaszczak-Kuligowska, P. Maras· Journal of Physics, Conferen...· 0 citations