Sep 2026· Medical Dosimetry· 0 citations· 24 references
Medicine
TL;DR
Despite its substantial weight and limited maximum field size, GRID-based SFRT offers straightforward treatment planning, efficient dose delivery, and the potential to enhance tumor control through its characteristic peak-to-valley dose distribution.
Abstract
Spatially Fractionated Radiation Therapy (SFRT) delivers high-dose radiation in a GRID pattern to treat large tumors. This can be achieved using either a physical GRID block or virtual MLC-based patterns. This report presents our experience commissioning a commercial brass GRID collimator for SFRT. Commissioning was performed using a brass GRID collimator with 6 MV and 10 MV photon beams under both flattening filter (FF) and flattening filter-free (FFF) configurations. Dosimetric measurements were collected in a water phantom and compared with treatment planning system calculations. SFRT test plans were created and validated using a commercial detector array. Valley-to-peak dose ratio (VPDR) ranged from 0.20 to 0.30 (6-MV) and 0.30 to 0.37 (10-MV). The Percent depth doses were lower than those for open fields at all beam energies. Measured vs. calculated profiles agreed within ±5% in dose and 1 mm in distance for all beam energies. TPS-generated plans showed strong agreement with measured distributions, with an average gamma passing rate of 96.5% (3%/3 mm criteria). We successfully commissioned and validated a commercial GRID collimator for SFRT using 6-MV and 10-MV photon beams in both FF and FFF modes. Despite its substantial weight and limited maximum field size of 25 × 25 cm², GRID-based SFRT offers straightforward treatment planning, efficient dose delivery, and the potential to enhance tumor control through its characteristic peak-to-valley dose distribution.
An initial 3D electronic detector array prototype for radiotherapy, consisting of 2645 diodes (8.0 mm pitch), was modelled with Geant4 and MCNP6.2 Monte Carlo codes to simulate irradiations of 2×2, 3×3, 4×4, and 5×5 cm2 field sizes with a 6 MV photon beam. Comparisons with Treatment Planning Software (TPS) data reveale...
R. Ocampo, D. Roa, Enzo Aucca et al.· Journal of Physics, Conferen...· 0 citations
Stereotactic radiosurgery delivers an ablative single-fraction dose to small intracranial targets, and the reported dose depends on the calculation algorithm. This exploratory case series quantified the change in reported dosimetry when plans clinically finalised with the anisotropic analytical algorithm (AAA) were rec...
K. Utitsarn, Thepphithak Watthanasarn, Wirasinee Chaloemchawalit et al.· Biomedical engineering and p...· 0 citations
Microbeam Radiotherapy (MRT) is an emerging radiotherapy technique which delivers spatially fractionated beams on a micrometre scale. In preclinical studies MRT has demonstrated superior normal tissue sparing compared to conventional radiotherapy while maintaining tumour control. However, MRT has traditionally been ach...
K. Kraus, L. Day, Jan J. Wilkens et al.· Radiation Oncology· 0 citations
Results indicate that the detector can provide reliable and reproducible data and demonstrate the applicability of active-matrix technology to experimental 3D dosimetry in radiotherapy.
D. Roa, M. Risco-Castillo, R. Romero et al.· Journal of Physics, Conferen...· 0 citations
Treatment-planning studies indicate potential dosimetric advantages of very high-energy electron (VHEE) radiotherapy for deep-seated tumours, but the dose models on which these studies rely have few experimental benchmarks above 100 MeV. Here, we report radiochromic film dosimetry of 150 and 200 MeV beams at CERN’s C...
Fabio S. D'Andrea, Adam Aitkenhead, R. Chuter et al.· Communications Physics· 0 citations