Skip to content
Open access

Clinical and functional outcome of arthroscopic anterior cruciate ligament reconstruction using autologous graft with biodegradable interference screw and adjustable loop endobutton: a prospective study

Sep 2026 · International Journal of Research in Orthopaedics · 0 citations · 12 references

TL;DR

Arthroscopic ACL reconstruction using an autologous hamstring graft with biodegradable interference screw and adjustable-loop Endobutton provides excellent functional outcomes, reliable knee stability, and a low complication rate, making it a safe and effective treatment for symptomatic ACL injuries.

Abstract

Background: Anterior cruciate ligament (ACL) injury is a common cause of knee instability, functional impairment, and increased risk of secondary meniscal injury and early osteoarthritis. Arthroscopic ACL reconstruction is the gold standard treatment for symptomatic ACL tears. Secure graft fixation using an autologous hamstring graft, biodegradable interference screw, and adjustable-loop Endobutton provides stable fixation, promotes graft incorporation, and facilitates early rehabilitation. Methods: This prospective observational study included 60 patients with symptomatic ACL rupture treated at the Department of Orthopaedics, Sardar Patel Medical College and Associated Group of Hospitals, Bikaner. Preoperative assessment included clinical examination, MRI, Lysholm score, IKDC grading, and stability tests. All patients underwent arthroscopic ACL reconstruction using an autologous hamstring graft with femoral fixation by an adjustable-loop Endobutton and tibial fixation using a biodegradable interference screw. Functional outcomes and complications were evaluated during follow-up. Results: The mean patient age was 28.9±6.3 years, and 81.7% were male. At final follow-up, 68.3% achieved an excellent Lysholm score, while 46.7% and 40.0% were graded as normal and nearly normal, respectively, on the IKDC scale. Most patients demonstrated restored knee stability with minimal complications. No implant failure, deep infection, or neurovascular injury was observed. Conclusion: Arthroscopic ACL reconstruction using an autologous hamstring graft with biodegradable interference screw and adjustable-loop Endobutton provides excellent functional outcomes, reliable knee stability, and a low complication rate, making it a safe and effective treatment for symptomatic ACL injuries.

Read PDF

Similar papers

Open access Oct 2026

Outcome of arthroscopic anterior cruciate ligament reconstruction by hamstring and medial collateral ligament reconstruction by peroneus longus autograft in anteromedial knee instability

Background: Combined anterior cruciate ligament (ACL) and medial collateral ligament (MCL) injuries are a common cause of anteromedial knee instability and often require surgical reconstruction to restore function and stability. This study evaluated the functional outcomes, knee stability and complications following ar...

Jobayer Al Mahmud, M. Hossain, Pathik Biswas et al. · 0 citations
Open access Oct 2026

Anterior cruciate ligament reconstruction with lateral extra-articular tenodesis in patients at high risk of rotational instability

Background: Despite advances in anterior cruciate ligament (ACL) reconstruction, residual rotational instability and graft failure remain concerns, particularly in high-risk patients. Lateral extra-articular tenodesis (LET) may improve rotational control and protect the ACL graft. To evaluate clinical outcomes of combi...

M. Hussain, Md Mahsin, Jannat Ul Alam Jisa et al. · 0 citations
Open access Oct 2026

A comparative analysis of cortical button and intratunnel fixation using interference screw for tibial fixation in anterior cruciate ligament reconstruction

Anterior cruciate ligament (ACL) reconstruction with hamstring tendon autografts depends on secure tibial graft fixation to ensure stability and healing. The two main methods, cortical button and interference screw fixation, are widely used, but existing evidence on their clinical and radiological outcomes is still...

R. Devgan, Sarita Dhankhar, Virender Kumar et al. · 0 citations
Open access Oct 2026

Arthroscopic Posterior Cruciate Ligament Tibial Spine Avulsion Fixation Using a Suture Pull-Through Single-Tunnel Technique

In this small single-center observational cohort, arthroscopic single-tunnel suture pull-through fixation was feasible and was associated with radiographic union and favorable short-term Lysholm score improvement, and should be interpreted as evidence of superiority or equivalence to other fixation techniques.

P. Patel, H. Rajpardhi, Lomesh P. Modi et al. · 0 citations
Open access Sep 2026

Accelerated Brace-Free Rehabilitation and Functional Outcome of Anterior Cruciate Ligament (ACL) Reconstruction with a Semitendinosus–Gracilis (STG) Graft: A Prospective Observational Study

Background: Anterior cruciate ligament (ACL) rupture commonly causes marked functional impairment. Reconstruction with a semitendinosus–gracilis (STG) graft is well accepted, and rehabilitation has shifted towards accelerated, brace-free protocols. Objectives: To evaluate the functional outcome and safety of an acceler...

Hiranya Kumar, Shashikumar Rathod, Shuchindra R. Chowdhary · 0 citations
Sep 2026

Outcomes after anterior cruciate ligament reconstruction with versus without lateral extra-articular tenodesis: A propensity-matched cohort study.

PURPOSE Lateral extra-articular tenodesis (LET) has gained increasing use as an adjunct to anterior cruciate ligament reconstruction (ACLR) to improve rotational stability and reduce graft failure. However, concerns remain regarding its potential impact on postoperative morbidity and longer-term joint outcomes. This st...

A. Rteil, Koh Jason, F. Amirouche · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.