Skip to content
Open access

Arthroscopic Posterior Cruciate Ligament Tibial Spine Avulsion Fixation Using a Suture Pull-Through Single-Tunnel Technique

Oct 2026 · Journal of Orthopaedic Case Reports · Vol 16, pp. 408 - 414 · 0 citations · 2 references
Medicine

TL;DR

In this small single-center observational cohort, arthroscopic single-tunnel suture pull-through fixation was feasible and was associated with radiographic union and favorable short-term Lysholm score improvement, and should be interpreted as evidence of superiority or equivalence to other fixation techniques.

Abstract

Abstract Introduction: Posterior cruciate ligament (PCL) tibial avulsion fractures are uncommon intra-articular injuries that may cause persistent posterior instability, loss of motion, and functional impairment if displaced fractures are not anatomically reduced. Arthroscopic suture pull-through fixation offers stable transosseous fixation while avoiding complications associated with screw fixation. Aim: The aim of this study was to evaluate the functional and radiological outcomes of arthroscopic PCL tibial avulsion fixation using a suture pull-through single-tunnel technique. Materials and Methods: A prospective, single-center observational study without a control group was conducted in the Department of Orthopedics, N.D. Desai Medical College, from May 2026 to July 2026. Twenty-four patients with displaced isolated PCL tibial avulsion fractures underwent arthroscopic single-tunnel suture pull-through fixation. Lysholm scores and radiological union were assessed at 6 weeks, 3 months, and 6 months; no instrumented posterior laxity testing or additional validated patient-reported outcome measure was available. Results: The cohort included 24 patients with a mean age of 28 years (range 18–60 years). The mean Lysholm score improved from 41.6 ± 3.2 preoperatively to 81.2 ± 5.6 at 6 weeks, 90.7 ± 3.5 at 3 months, and 94.9 ± 2.3 at 6 months (Friedman P < 0.001). All fractures were recorded as united by 3 months on follow-up radiographs, and 22 patients (approximately 92%) reported return to their pre-injury activity level within 4–6 months. One patient developed a mild extension lag that improved with physiotherapy. No non-union, fixation failure, or revision surgery was observed during the 6-month follow-up; however, objective posterior translation was not measured. Conclusion: In this small single-center observational cohort, arthroscopic single-tunnel suture pull-through fixation was feasible and was associated with radiographic union and favorable short-term Lysholm score improvement. Because there was no comparator group, objective posterior stability testing, or long-term follow-up, these findings should not be interpreted as evidence of superiority or equivalence to other fixation techniques.

Read PDF

Similar papers

Open access Sep 2026

Arthroscopic Fixation of Posterior Cruciate Ligament Tibial Avulsion Fractures With Single‐Suture and Dual EndoButtons via the Lateral Aspect of the Anterior Cruciate Ligament

Abstract Arthroscopic techniques have gradually replaced open surgery as a routine method for treating posterior cruciate ligament tibial avulsion fractures. However, traditional arthroscopic surgery is associated with problems such as limited visualization, unstable fixation, and unsatisfactory reduction. By comparing...

Si-Qi Yang, Sheng-Kun Wu, Zhi-Kuan Li et al. · 0 citations
Open access Sep 2026

Clinical and functional outcome of arthroscopic anterior cruciate ligament reconstruction using autologous graft with biodegradable interference screw and adjustable loop endobutton: a prospective study

Arthroscopic ACL reconstruction using an autologous hamstring graft with biodegradable interference screw and adjustable-loop Endobutton provides excellent functional outcomes, reliable knee stability, and a low complication rate, making it a safe and effective treatment for symptomatic ACL injuries.

B. Khajotia, Manish Choudhary, P. Singh et al. · 0 citations
Open access Oct 2026

A comparative analysis of cortical button and intratunnel fixation using interference screw for tibial fixation in anterior cruciate ligament reconstruction

Anterior cruciate ligament (ACL) reconstruction with hamstring tendon autografts depends on secure tibial graft fixation to ensure stability and healing. The two main methods, cortical button and interference screw fixation, are widely used, but existing evidence on their clinical and radiological outcomes is still...

R. Devgan, Sarita Dhankhar, Virender Kumar et al. · 0 citations
Open access Oct 2026

Posterior Cruciate Ligament Avulsion Fracture with Non-Displaced Patellar Fracture: A Case Report

An avulsion fracture of the posterior cruciate ligament (PCL) occurs when the ligament pulls a fragment of bone away from its attachment site rather than tearing through its own substance. It’s a rare injury and is missed most often, particularly when associated with multiple injuries or fractures around the knee and h...

A. Zaizi, O. Azriouil, N. El Ghoule et al. · 0 citations
Case report Sep 2026

A Distinct Posterior Cruciate Ligament Avulsion Fracture Involving the Weight-bearing Lateral Tibial Plateau as a Single Fragment: A Case Report.

Posterior cruciate ligament (PCL) avulsion fractures usually involve the tibial insertion as a discrete fragment. Although combined PCL avulsion and tibial plateau fractures have been described, a continuous fracture fragment involving both the PCL insertion and the weight-bearing lateral tibial plateau is rarely repor...

Young Lee, Hong-Sen Chiang, Tzu-Hao Tseng · 0 citations
Case report Sep 2026

Suture Anchor Fixation Combined With Transosseous Tunnels for a Large Patellar Osteochondral Fracture After Acute Patellar Dislocation.

Patellar osteochondral fractures (OCFs) are common concomitant injuries in acute patellar dislocation, particularly in adolescents. Large free fragments (>15 mm in diameter) are relatively rare and require surgical reduction and fixation to restore articular surface congruity and prevent mechanical symptoms and seconda...

Jing-Xin Li, Li Gong, Ming Zhou · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.