Oct 2026· IEEE Transactions on Plasma Science· Vol 54, pp. 5206-5219· 0 citations· 35 references
Abstract
The increasing adoption of DC technologies in distribution networks, electric vehicles, and photovoltaic systems necessitates reliable DC fault current interruption. Electromechanical DC switches, known for their low power loss and compactness, face challenges due to arcing phenomena. While previous studies have shown that magnetic fields can elongate arcs and enhance cooling by increasing airflow velocity, they often neglect the influence of contact motion on arc behavior across different interruption stages. Among these, transient airflow behavior remains particularly difficult to characterize experimentally due to the limitations of high-speed imaging and flow diagnostics. This study develops a 2-D model of a DC switching device using COMSOL multiphysics, incorporating magnetohydrodynamics (MHDs) and a simplified near-electrode model that approximates the nonequilibrium sheath and adjacent ionization layers as a single effective boundary layer (BL) with fixed voltage and heat flux conditions to efficiently simulate arc-electrode interactions. The remaining 3-D feature (arc depth) is defined as a function of time and contact moving velocity, derived from experimental observations. Coupling the model with an external circuit enables realistic analysis under practical operating conditions. Simulation results closely align with experimental data, identifying three distinct arc evolution stages: Stage 1, where arc inside the contact structure; Stage 2 as the arc moves outside into the expansion chamber; and Stage 3, where the arc is extinguished. An energy-based analysis reveals the dominant factor at each stage: whether it is the contact motion, the external magnetic field, or their combination. Across all simulated cases, arc extinction occurred only after the arc power reached its maximum, corresponding to the point where the arc absorbs half of the power available from the supply. This indicates that accelerating the resistance rise during Stage 2 to reach this point sooner is key to achieving faster and more reliable arc interruption.
High-voltage vacuum circuit breakers are key switching equipment for power grids. Vacuum arc stability and axial magnetic field (AMF) distribution govern the short-circuit breaking performance and insulation reliability of vacuum interrupters under heavy short-circuit currents. Contact radius (electrode diameter) and g...
Cumulative electrical erosion during repeated interruption is a key factor limiting the service lifetime of low-voltage direct current switching devices. In this work, the cumulative erosion behavior of air-switch contacts under magnetically blown arcs was investigated through experiments and numerical simulations. The...
Jing Li, Y. Wang, Wei Duan et al.· Journal of Physics D: Applie...· 0 citations
During the tripping of a direct current (DC) vacuum circuit breaker, a plasma arc is generated between the contacts. Different tripping speeds alter the plasma diffusion space between the contacts, affecting the plasma’s longitudinal and axial diffusion rates. Under identical commutation gap conditions, tripping speed...
Chong-Yang Huang, Fei-Ran Zhang, S. Fu et al.· Engineering Research Express· 0 citations
The interruption reliability of DC circuit breakers hinges on the competition between transient recovery voltage (TRV) and dielectric recovery, with TRV being highly sensitive to arc parameters. To investigate this post-arc voltage recovery process, we develop a two-dimensional magnetohydrodynamic (MHD) arc model that...
Magnetic field control is critical for successful high-current interruption in vacuum circuit breakers. High-capacity vacuum switchgear has broad prospects in renewable energy-dominated power systems. This paper investigates the magnetic field characteristics of the high-capacity cup-shaped contacts under various gaps...