Geometry-hemodynamics relationships in the vertebral artery V1 segment: A patient-specific CFD and multivariable analysis

Sep 2026 · Journal of Mechanics in Medicine and Biology · 0 citations

TL;DR

Diameter-related geometric features, particularly the proximal and distal SA diameters, exert stronger and more consistent independent associations with local hemodynamic characteristics than tortuosity-related descriptors in the VA V1 segment and provide quantitative evidence for future patient-specific hemodynamic assessment.

Abstract

Vascular geometry influences local hemodynamic conditions in the vertebral artery (VA), but the independent contributions of different morphological characteristics remain insufficiently understood. This study aimed to identify the independent morphological determinants of hemodynamic characteristics in the VA V1 segment. Thirty patient-specific bilateral VA V1 models reconstructed from computed tomography angiography were analyzed using computational fluid dynamics. Hemodynamic parameters, including time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT), together with time-averaged nitric oxide concentration (TANO), were quantified. Generalized linear mixed models (GLMMs) were applied to evaluate independent geometry-hemodynamics associations while accounting for bilateral dependence and adjusting for age, sex, and vascular side. Side-specific generalized linear and Beta regression analyses were further performed. Pronounced left-right differences were observed in vascular geometry and hemodynamics. After multivariable adjustment, the proximal and distal subclavian artery (SA) diameters emerged as the most consistent independent predictors of WSS- and NO-related metrics. In contrast, the significant associations between VA tortuosity and hemodynamic metrics observed in univariate analyses were substantially attenuated after adjustment for confounding factors. Side-specific analyses revealed distinct geometry-hemodynamics relationships between the left and right VAs under the corresponding side-specific inlet conditions. Diameter-related geometric features, particularly the proximal and distal SA diameters, exert stronger and more consistent independent associations with local hemodynamic characteristics than tortuosity-related descriptors in the VA V1 segment. Geometry-hemodynamics relationships also differed between the left and right VAs under side-specific physiological inlet conditions, highlighting the need to consider both vascular anatomy and flow boundary conditions in patient-specific hemodynamic analysis. These findings improve understanding of geometry-dependent hemodynamic variation in the VA V1 segment and provide quantitative evidence for future patient-specific hemodynamic assessment.

View source

Similar papers

Open access Oct 2026

Hemodynamic and Geometrical Parameters Associated with Carotid Artery Stenosis: A Cross-Sectional Study Using 4D Flow MRI and CFD.

PURPOSE Carotid geometry and local hemodynamics are closely associated with atherosclerosis, yet how anatomy and disturbed flow jointly mark disease presence and relate to pro-atherogenic flow in still-non-stenosed bifurcations remains unresolved. This study quantifies the cross-sectional association between three-dime...

Ali Mokhtari, Ariel Bergmann, C. Strecker et al. · 1 citation
Open access Oct 2026

Clinical correlation of hemodynamic parameters using blood flow prediction model in cerebrovascular arteries

Introduction Patient-specific hemodynamic assessment is pivotal for optimizing treatment strategies in cerebrovascular interventions; however, conventional modalities are often limited by restricted clinical accessibility or prolonged acquisition times. Methods This study evaluates the previously developed Dr. NEAR flo...

J. Kim, Wheesung Lee, Young-Lin Yoo et al. · 0 citations
Open access Sep 2026

Impact of Aging, Sex, and Hypertension on Aortoiliac Hemodynamics: A 4-Dimensional Flow Magnetic Resonance Imaging Study.

BACKGROUND The impact of aging, sex, and hypertension on the aortoiliac arterial system is poorly characterized. This study aimed to comprehensively evaluate iliac artery hemodynamics and the vascular aging phenotype using 4-dimensional flow magnetic resonance imaging. METHODS In this cross-sectional study, 235 parti...

Qi-Ming Liu, Xin-Yu Wang, Julio A. Sotelo et al. · 0 citations
Open access Sep 2026

Fully coupled patient-specific fluid–structure interaction modeling of post-TAVI hemodynamics compared with echocardiographic measurements

To develop a fully coupled, patient-specific fluid–structure interaction (FSI) framework for quantitative assessment of post–transcatheter aortic valve implantation (TAVI) hemodynamics and valve biomechanics, and to compare selected simulation-derived hemodynamic indices with post-procedural echocardiographic measureme...

Chiara Catalano, D. Ozturk, Maria Bastron et al. · 0 citations