Skip to content
Preprint

Comparative Evaluation of Carotid Artery Hemodynamics: Patient-Specific CFD Simulations vs. 4D flow MRI

Sep 2026 · 0 citations · 59 references
Physics

TL;DR

MRI-derived plaque-surface WSS showed magnitude- and location-dependent disagreement with CFD, greater in more severely stenosed arteries and, in exploratory analyses, associated with factors beyond stenosis degree.

Abstract

Wall shear stress (WSS) is implicated in carotid atherosclerosis, and 4D flow MRI offers a non-invasive route to its estimation, but the agreement of MRI-derived plaque-surface WSS with computational fluid dynamics (CFD) has not been quantified in a large cohort. We compared peak-systolic velocity and WSS from 4D flow MRI and patient-specific CFD in 240 carotid arteries of 120 patients, with CFD geometries and boundary conditions derived from MRI. Velocity and circumferential WSS were compared at three standardized cross-sections, and plaque-surface WSS in 63 of 149 stenosed arteries with a reliably segmented plaque. Agreement was assessed with Bland-Altman analysis, Spearman correlation with stenosis degree, and exploratory multivariable regression of the plaque-surface discrepancy on hemodynamic and geometric variables. MRI reproduced the broad flow features but underestimated peak velocity, increasingly toward the distal internal carotid artery. WSS disagreement was location dependent: mean circumferential WSS showed little average bias in the common carotid artery, whereas MRI missed the high WSS at the bifurcation apex and underestimated plaque-surface mean and maximum WSS by $40.9 \pm 28.8\%$ and $44.5 \pm 26.8\%$; the difference in Pa increased with stenosis degree ($\rho = 0.47$ and $0.50$). In exploratory regression, the CFD-derived pressure drop across the plaque was the only significant correlate of the mean WSS discrepancy, whereas stenosis degree and geometric variables were associated with the maximum WSS discrepancy. Under the present protocol, MRI-derived plaque-surface WSS showed magnitude- and location-dependent disagreement with CFD, greater in more severely stenosed arteries and, in exploratory analyses, associated with factors beyond stenosis degree.

View source

Similar papers

Open access Oct 2026

Hemodynamic and Geometrical Parameters Associated with Carotid Artery Stenosis: A Cross-Sectional Study Using 4D Flow MRI and CFD.

PURPOSE Carotid geometry and local hemodynamics are closely associated with atherosclerosis, yet how anatomy and disturbed flow jointly mark disease presence and relate to pro-atherogenic flow in still-non-stenosed bifurcations remains unresolved. This study quantifies the cross-sectional association between three-dime...

Ali Mokhtari, Ariel Bergmann, C. Strecker et al. · 1 citation
Open access Aug 2026

Validation of individualized flow simulations for determining the pressure gradient in patients with renal artery stenosis

Objectives To validate two computational fluid dynamics (CFD) models derived from computed tomography angiography (CTA) for estimating trans-stenotic pressure gradients, using invasive intra-arterial pressure measurements as the reference standard in patients with renal artery stenosis (RAS). Background We assessed whe...

T. Bouwmeester, D. Collard, I. Zijlstra et al. · 0 citations
Open access Sep 2026

Wall shear stress in coronary arteries and grafts using computational fluid dynamics and physics-informed neural networks

Compared with the Newtonian model, the Carreau–Yasuda formulation captured shear-rate-dependent viscosity effects in stenotic and bifurcation regions, and showed strong agreement with CFD results within their respective training geometries.

M. U. Ur Rehman, Ö. Ekici, Ş. E. Erdener et al. · 0 citations
Open access Sep 2026

Influence of pulsatile inlet waveforms on hemodynamics in a severely stenosed carotid artery: A CFD study

Carotid artery stenosis is a major contributor to ischemic stroke, a leading cause of death and long-term disability worldwide [Lopez et al., Lancet 367, 1747–1757 (2006) and WHO, Stroke fact sheet, 2023]. Accurate hemodynamic modeling of stenosed carotid arteries is essential for understanding atherosclerosis progress...

M. M. Rahman, M. Akhter · 0 citations
Open access Oct 2026

Clinical correlation of hemodynamic parameters using blood flow prediction model in cerebrovascular arteries

Introduction Patient-specific hemodynamic assessment is pivotal for optimizing treatment strategies in cerebrovascular interventions; however, conventional modalities are often limited by restricted clinical accessibility or prolonged acquisition times. Methods This study evaluates the previously developed Dr. NEAR flo...

J. Kim, Wheesung Lee, Young-Lin Yoo et al. · 0 citations
Sep 2026

Geometry-hemodynamics relationships in the vertebral artery V1 segment: A patient-specific CFD and multivariable analysis

Diameter-related geometric features, particularly the proximal and distal SA diameters, exert stronger and more consistent independent associations with local hemodynamic characteristics than tortuosity-related descriptors in the VA V1 segment and provide quantitative evidence for future patient-specific hemodynamic as...

Chang Liu, Jing Xu, Yang-Chen Li et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.