Developing the Readout Electronics for a Custom 64 × 64 SPAD Array: From Single-Board Prototyping to FPGA Implementation Toward Stellar Intensity Interferometry
Sep 2026· Italian National Conference on Sensors· Vol 26, pp. 5757· 0 citations· 44 references
Medicine
Abstract
Single-photon avalanche diode (SPAD) arrays enable photon-starved applications, including time-of-flight imaging and stellar intensity interferometry. Their astronomical use remains scarcely explored, as the bottleneck is usually not detection but rather acquisition electronics for high-rate event streams. This work presents a modular, event-driven acquisition system for a 64 × 64 SPAD array within the La Palma Quantum Interferometer (LPQI) project, repurposing a LiDAR detector for multi-telescope interferometry. Two stages are used: a Raspberry Pi 5 with a custom board for validation, and an AMD Kria KR260 (Zynq UltraScale+ MPSoC) implementing the Address-Event Representation (AER) handshake in hardware at 100 MHz. The system streams AER events without per-event timestamping; sub-nanosecond time-tagging is left for a future stage based on the White Rabbit protocol. Optical bench tests confirmed spatial detection and localization of photons at a measured throughput of up to ≈124 keps under the highest illumination condition tested, and dark-count-rate characterization showed a rate below 10 Hz for most pixels (median: 1.68 Hz at 27.8 °C); raw per-pixel event-count maps further confirmed, for the first time on this array, the expected 2 × 2 spatial pattern of inter-pixel crosstalk from its shared-cathode pixel groups. The results demonstrate the feasibility of repurposing a LiDAR SPAD sensor and establish an acquisition-electronics baseline to aid the development of a timestamped, multi-telescope system for deployment on five telescopes of the Roque de los Muchachos Observatory.
A dedicated data acquisition (DAQ) system has been developed for the SUB-Millicharge ExperimenT (SUBMET) at the Japan Proton Accelerator Research Complex (J-PARC), a search for particles carrying a fractional electric charge $Q = \epsilon e$ with $\epsilon$ below $\mathcal{O}(10^{-3})$, hereafter referred to as millich...
C. Campagnari, S. Cho, Su-Yong Choi et al.· 0 citations
Time-correlated single-photon counting (TCSPC) is the method of choice for high-resolution time-resolved measurements due to its exceptional temporal precision. Recent advances have demonstrated that TCSPC is no longer confined to the single-photon regime, as pile-up distortion, particularly severe under high illuminat...
G. Fratta, P. Daniele, Simone Basile et al.· IEEE Transactions on Instrum...· 0 citations
Accurate neutron beam profiling and position verification are required for alignment, improvement of signal-to-noise, and imaging development, yet are often performed with single-use beam-imaging media that provide only integrated exposure and limited real-time feedback. We present a first analysis of neutron imaging d...
D. Král, A. Stamatopoulos, A. Couture et al.· Journal of Physics, Conferen...· 0 citations
Transition-edge sensor (TES) microcalorimeters for future X-ray space observatories require accurate low-energy calibration, a regime where conventional X-ray sources are limited by intrinsic linewidth, count rate, or experimental complexity. In this work, we investigate fiber-coupled optical photons as a compact calib...
Giacomo Gorla, B. Sohl, E. Taralli et al.· Italian National Conference...· 0 citations
To address the susceptibility of single-photon avalanche diodes (SPADs) to false triggering under strong background illumination and the lack of flexibility in traditional macro-pixel readout architectures, this paper proposes an FPGA-based adaptive and reconfigurable macro-pixel SPAD array readout circuit. The design...
Yi-Ling Zeng, Fei Yuan, Na Tian et al.· IEEE Photonics Journal· 0 citations
The cooler-storage-ring (CSR) external-target experiment (CEE) at the Heavy Ion Research Facility in Lanzhou (HIRFL) requires a non-interceptive beam particle monitor (BPM) for accurate primary vertex reconstruction and background suppression. Traditional beam diagnostics fail to meet the simultaneous requirements of h...
Ran Chen, Jun Liu, H. Wang et al.· IEEE Transactions on Nuclear...· 0 citations