Asymmetric biphasic pulsed field ablation of paroxysmal atrial fibrillation: clinical assessment

Oct 2026 · Frontiers in Cardiovascular Medicine · Vol 13 · 0 citations · 41 references

TL;DR

An asymmetric biphasic PFA system that combines a unique pulse-parameter configuration with a dedicated, adjustable six-spline catheter showed a favorable safety profile, with few SCLs and no hemolysis-related AKI, and 12-month effectiveness was within the range reported in previous studies of PFA technologies.

Abstract

Pulsed field ablation (PFA) is a non-thermal, tissue-selective therapy for atrial fibrillation. In this study, we evaluated the safety and efficacy of a novel asymmetric biphasic PFA system, which combines a unique pulse-parameter configuration with a dedicated, adjustable six-spline catheter. This prospective, multicenter, single-arm study was conducted in China. Patients with drug-refractory paroxysmal AF underwent pulmonary vein isolation (PVI) using a 1,000 V asymmetric biphasic PFA system with a novel parameter configuration. The primary effectiveness endpoint was freedom from atrial arrhythmia recurrence through 12 months post-blanking. The primary safety endpoint was predefined serious adverse events. The secondary safety endpoint was hemolysis and silent cerebral lesions (SCLs). Among 120 enrolled patients, 105 underwent ablation and completed the 12-month follow-up, while 15 patients withdrew before the PFA operation. Acute PVI was successfully achieved in all 420 targeted veins. At 12 months, the Kaplan–Meier estimate of freedom from atrial arrhythmia recurrence was 69.5% (95% CI, 60.1–77.5%). The observed 12-month effectiveness was within the range reported in previous studies of PFA technologies. Regarding safety, major procedural complications—including pulmonary vein stenosis, phrenic nerve injury, atrioesophageal fistula, stroke, and acute kidney injury (AKI)—were entirely absent. However, one patient (0.95%) experienced a transient coronary vasospasm that was successfully resolved with an intracoronary vasodilator. Additionally, SCLs were detected in two patients (1.9%). While laboratory hemolysis was a common finding, it did not lead to renal impairment. This asymmetric biphasic PFA system achieved complete acute PVI and 12-month effectiveness was within the range reported in previous studies of PFA technologies. It showed a favorable safety profile, with few SCLs and no hemolysis-related AKI. https://www.chictr.org.cn/showproj.html?proj=134973 , identifier ChiCTR2200062157.

Read PDF

Similar papers

Open access Sep 2026

Pulsed Field Ablation for Atrial Fibrillation in Australia: A Large Tertiary Centre Analysis.

BACKGROUND Pulsed field ablation (PFA) is increasingly used for catheter ablation of atrial fibrillation (AF). Limited real-world data exists regarding safety and efficacy of PFA in Australia. METHOD We conducted a retrospective analysis of consecutive patients undergoing de novo PFA for paroxysmal or persistent AF a...

Francis J. Ha, Duron Prinsloo, Edwin Xu et al. · 0 citations
Sep 2026

Safety, Efficacy, and Effectiveness of Pulsed Field Ablation with Farapulse™ to Treat Atrial Fibrillation: A Prospective Single-center Study

Pulsed field ablation (PFA) using the Farapulse™ system (Boston Scientific, Marlborough, MA, USA) is a novel, non-thermal ablation technology developed to treat atrial fibrillation (AF) with improved safety and procedural efficiency. We present prospective single-center data on the safety, efficacy, and effectiveness o...

Dean Sabayon, Deaa Abu Jazar, K. Alabdallah et al. · 0 citations
Review Open access Oct 2026

Treatment of paroxysmal and persistent atrial fibrillation with pulsed field ablation

Abstract Pulsed field ablation has emerged as a novel energy source for atrial fibrillation ablation, offering preferential myocardial ablation with a favourable safety profile. Contemporary paroxysmal AF clinical studies demonstrate 12-month freedom from atrial arrhythmia recurrence in approximately 75-85% of patients...

S. Boveda, K.-R.-J. Chun, P. Jaïs et al. · 0 citations
Open access Sep 2026

Characteristics of Recurrent Atrial Arrhythmias and Lesion Assessment Late After Pulsed Field Ablation of Atrial Fibrillation

In patients undergoing redo procedures after an initial AF ablation using the pentaspline PFA catheter, AF was less frequently observed when ablation lesions were performed beyond PVs and a high rate of durable PVI or block was achieved with >12 PFA applications per PV and >16 for the roof/PW.

M. Beneyto, Corentin Chaumont, Masaaki Yokoyama et al. · 0 citations
Open access Aug 2026

Safety and Effectiveness of a Novel Dual-Energy Radiofrequency/Pulsed Field Ablation Catheter: 12 Month Results of the FlexPulse Study.

BACKGROUND AND AIMS Pulsed field (PF) ablation is increasingly used to treat paroxysmal atrial fibrillation (PAF). FlexPulse (NCT06676072) was conducted to evaluate safety and effectiveness of a novel dual-energy, flexible-tip focal ablation catheter with radiofrequency and PF for treatment of symptomatic, drug-refract...

Ayman A. Hussein, G. Račkauskas, S. Sundaram et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.