Skip to content
Open access

Characteristics of Recurrent Atrial Arrhythmias and Lesion Assessment Late After Pulsed Field Ablation of Atrial Fibrillation

Sep 2026 · Circulation: Arrhythmia and Electrophysiology · Vol 19, pp. e014506 - e014506 · 0 citations · 26 references
Medicine

TL;DR

In patients undergoing redo procedures after an initial AF ablation using the pentaspline PFA catheter, AF was less frequently observed when ablation lesions were performed beyond PVs and a high rate of durable PVI or block was achieved with >12 PFA applications per PV and >16 for the roof/PW.

Abstract

Background

Pulsed field ablation (PFA) is a novel and rapidly expanding energy for the ablation of atrial fibrillation (AF). The relationships between the characteristics of pulmonary vein (PV) and extra-PV PFA applications, and the type of arrhythmia recurrence or durable lesion observed during redo procedures remain unclear.

Methods

In this substudy of the FRANCE PFA national exhaustive multicentric registry, we collected detailed data on PFA applications delivered during the initial AF ablation procedure. Among patients with arrhythmia recurrence undergoing redo procedures with 3-dimensional mapping (n=145), we analyzed the type of recurrence, rates of durable PV isolation (PVI), and the presence of complete block over the ablation lines.

Results

Recurrent arrhythmias comprised AF in 58%, atrial tachycardia in 23%, and typical atrial flutter in 9%. AF was less frequently observed when initial ablation targeted extra-PV areas (45 versus 71%; P=0.01) and when a 35-mm diameter catheter was used for PVI only (50 versus 77%; P=0.01). Complete durable PVI was observed in 42% of patients (69% to 76% for each separate PV), and durable roof/PW and mitral isthmus blocks were observed in 62% and 31% of cases, respectively. The rate of durable PVI increased with the number of PFA applications (P<0.05), reaching 84% with >12 applications. Similarly, roof/PW block rates increased to 88% with >16 applications (P<0.01). Mitral isthmus block rate remained low (31%) and was not significantly associated with application number.

Conclusions

In patients undergoing redo procedures after an initial AF ablation using the pentaspline PFA catheter, AF was less frequently observed when ablation lesions were performed beyond PVs. A high rate of durable PVI or block was achieved with >12 PFA applications per PV and >16 for the roof/PW. Long-term durability of mitral isthmus block was poor using the Pentaspline PFA catheter.

Read PDF

Similar papers

Open access Sep 2026

Pulsed Field Ablation for Atrial Fibrillation in Australia: A Large Tertiary Centre Analysis.

BACKGROUND Pulsed field ablation (PFA) is increasingly used for catheter ablation of atrial fibrillation (AF). Limited real-world data exists regarding safety and efficacy of PFA in Australia. METHOD We conducted a retrospective analysis of consecutive patients undergoing de novo PFA for paroxysmal or persistent AF a...

Francis J. Ha, Duron Prinsloo, Edwin Xu et al. · 0 citations
Open access Sep 2026

Left atrial anatomy and atrial arrhythmia recurrence after pulsed-field ablation.

BACKGROUND The impact of left atrial (LA) anatomical features on atrial arrhythmia (AA) recurrence after pulsed-field (PF)-based pulmonary vein isolation (PVI) is unknown. This study aimed to assess LA anatomical features associated with long-term AA recurrence after PVI. METHODS We prospectively enrolled patients un...

M. Mutti, D. Spreen, Jonas Brügger et al. · 0 citations
Open access Sep 2026

Direct Atrial Fibrillation Termination During Pulsed Field Ablation: Association With Intracardiac Cycle Length.

BACKGROUND Pulsed field ablation (PFA) enables rapid and tissue-selective pulmonary vein isolation (PVI). However, the electrophysiological determinants of direct atrial fibrillation (AF) termination during PFA remain unclear. OBJECTIVE To investigate the clinical and electrophysiological characteristics associated w...

Eiji Yoshida, Yusuke Sakamoto, Hiroyuki Osanai · 0 citations
Open access Sep 2026

Individualized radiofrequency ablation of non-paroxysmal atrial fibrillation based on mapping of spatiotemporal dispersion zones: clinical results

Aim. to evaluate the results of pulmonary vein isolation (PVI) and spatio-temporal dispersion (STD) radiofrequency ablation (RFA) and the recurrence rate of atrial fibrillation (AF) in patients with non-paroxysmal AF after intraoperative intravenous administration of novocainamide. Methods. The study included...

N. Makarova, S. S. Durmanov, R. Ushakov et al. · 0 citations
Open access Oct 2026

Asymmetric biphasic pulsed field ablation of paroxysmal atrial fibrillation: clinical assessment

An asymmetric biphasic PFA system that combines a unique pulse-parameter configuration with a dedicated, adjustable six-spline catheter showed a favorable safety profile, with few SCLs and no hemolysis-related AKI, and 12-month effectiveness was within the range reported in previous studies of PFA technologies.

Xin-Yu Xu, Yun-Fan Li, Feng-Min Lu et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.