Skip to content

Anterior Chamber Angle Alterations in Bilateral Acute Iris Transillumination Syndrome.

Sep 2026 · Ocular immunology and inflammation · pp. 1-10 · 0 citations · 13 references
Medicine

TL;DR

BAIT may be associated with measurable alterations in anterior chamber angle configuration characterized predominantly by reduced AOD and TISA values, which are associated with measurable alterations in anterior chamber angle configuration characterized predominantly by reduced AOD and TISA values.

Abstract

Purpose

To evaluate anterior chamber angle characteristics in patients with bilateral acute iris transillumination (BAIT) using swept-source anterior segment optical coherence tomography (AS-OCT) and to investigate the diagnostic performance of angle parameters for distinguishing BAIT from healthy controls.

Methods

This cross-sectional study included 15 patients diagnosed with BAIT and 15 healthy controls with a comparable age and sex distribution. All participants underwent comprehensive ophthalmic examination and anterior segment imaging using the ANTERION swept-source AS-OCT system. Measurements included angle opening distance (AOD), trabecular-iris space area (TISA), scleral spur angle (SSA), aqueous depth (AQD), lens thickness, lens vault, and other anterior segment biometric parameters. Group comparisons were performed. Correlation analyses were conducted to evaluate associations between angle parameters and ocular biometric measurements. Receiver operating characteristic (ROC) analysis was performed to assess the diagnostic utility of significant angle parameters.

Results

Patients with BAIT demonstrated significantly lower AOD and TISA values compared with healthy controls, whereas SSA measurements were comparable between groups. Correlation analysis revealed significant positive associations of AOD, TISA, and SSA measurements with AQD and significant negative associations with lens thickness. ROC analysis demonstrated good discriminatory ability for both AOD750 MIN and TISA750 MIN in distinguishing BAIT eyes from controls. Mean intraocular pressure decreased from 24.4 ± 16.2 mmHg at presentation to 14.7 ± 2.1 mmHg at 12 months, although the difference was not statistically significant (p = 0.226).

Conclusions

BAIT may be associated with measurable alterations in anterior chamber angle configuration characterized predominantly by reduced AOD and TISA values.

View source

Similar papers

Open access Oct 2026

Evaluation of axial length measurement and other biometric parameters using three different generations of biometers

Purpose To compare biometric measurements obtained with partial coherence interferometry (IOLMaster 500, IOLM), optical low-coherence reflectometry (Lenstar 900, LS900), and swept-source optical coherence tomography (Eyestar 900, ES900). Methods In this prospective, observational study, axial length (AL), anterior cham...

Ferdinando Cione, Domenico Mucci, Isabella Pellegrino et al. · 0 citations
Open access Sep 2026

Diagnostic ability of Cirrus anterior segment optical coherence tomography to differentiate between binary grades of narrow angles seen on gonioscopy

Purpose: To assess diagnostic performance of Cirrus Anterior Segment Optical Coherence Tomography (ASOCT) parameters to differentiate gonioscopic grades of narrow angles. Methods: This prospective cross sectional study included 100 eyes with clinically diagnosed angle closure disease. Quantitative ASOCT parameters such...

V. Chelerkar, Vidhi Solanki, V. Kalyani et al. · 0 citations
Open access Oct 2026

Comparison of Biometric Measurements Between Anterior Segment Hyperparallel and Swept-Source Optical Coherence Tomography

Purpose To evaluate the inter-device agreement between hyperparallel optical coherence tomography (HP-OCT) and swept-source OCT (SS-OCT) in quantitative anterior segment parameters. Methods Phakic subjects aged ≥40 years were consecutively recruited at a tertiary eye hospital. Horizontal B-scans (0°–180°) were analyzed...

A. Servillo, Natalia Porporato, B. Tan et al. · 0 citations
Open access Aug 2026

Role of Anterior Segment Optical Coherence Tomography in Angle Closure Glaucoma

Objective: To evaluate the anterior chamber angles in acute angle closure glaucoma for early detection and prompt treatment. Study Design: Prospective Analytical study Place and Duration of Study: Armed Forces Institute of Ophthalmology Rawalpindi, Pakistan from Jan 2023 to Aug 2024. Methodology: This study involved 34...

Sheena Liaquat, M. A. Mukhtar, Aaiza Tahir et al. · 0 citations
#software testing Open access Oct 2026

Anterior Scleral Thickness in Young Saudi Adults Measured Using Swept-Source Optical Coherence Tomography: Sex- and Quadrant-Specific Variations

Purpose: To report baseline anterior scleral thickness (AST) values and evaluate regional and sex-related variation in healthy young Saudi adults using swept-source optical coherence tomography (SS-OCT). Methods: A prospective, cross-sectional study included 55 healthy Saudi adults aged 18–40 years. Participants underw...

N. Challa, Nawaf M. Almutairi, Bandar M. Alenezi et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.