Cardiac-Net: A Wearable ECG Prototype and Hybrid CNN–Transformer Model for Atrial Fibrillation Detection in Long-Term ECG Recordings

Oct 2026 · BioMedInformatics · 0 citations · 27 references

Abstract

Postoperative atrial fibrillation (POAF) is a leading cause of stroke and mortality after cardiac surgery, motivating continuous long-term ECG monitoring.This paper presents Cardiac-Net, a wearable ECG system (ESP32-S3/AD8232 BLE device with a Flutter mobile gateway; 128 Hz nominal/85 Hz effective BLE sampling rate, 12.6 ms mean latency, zero over-the-air loss of transmitted packets, 3.11 mJ per transmitted sample) combined with a hybrid 1D CNN–Transformer classifier and a proposed cloud-assisted monitoring architecture; the cloud inference and monitoring-dashboard layer is a design-level proposal only and has not been implemented. Bench signal fidelity, validated against a BIOPAC MP36 reference using a Fluke ProSim 8 simulator across five noise conditions, yields a Pearson Correlation Coefficient of 0.9222 and BPM errors below 0.2% under clean conditions, within the 5% heart-rate-error threshold specified by IEC 60601-2-47. The classifier was trained and evaluated on the Long-Term Atrial Fibrillation Database (84 recordings) using a record-wise (patient-wise) data split with verified zero overlap between training, validation, and test recordings; 5-fold record-wise cross-validation spanning all 84 recordings yields AUC =0.953±0.016, F1 =0.894±0.030, precision =0.880±0.051, and recall =0.915±0.073; re-evaluating at the device’s actual 85 Hz effective throughput confirms comparable discrimination (AUC =0.946±0.010) alongside a real increase in false-alarm burden. A clinical evaluation protocol beyond segment-level accuracy shows that most AF episodes are detected (episode-level sensitivity 0.839±0.222 by fold; per-patient median 1.000, IQR [0.925, 1.000]), but this is not uniform across patients: 7.2% (6/83) fall below chance-level detection. Combined with a false-alarm burden of 86±38 alerts per patient-day and a prevalence-adjusted positive predictive value of only 0.28–0.44 at 5–10% assumed AF prevalence, alarm calibration and patient-level reliability both remain barriers to unsupervised clinical deployment. Zero-shot evaluation on the independent MIT-BIH Atrial Fibrillation Database, with no fine-tuning, yields an ensemble AUC of 0.834, indicating generalization beyond the training distribution alongside a measurable domain gap. Post-hoc Grad-CAM and Integrated Gradients attributions are consistent with physiologically grounded decision-making, concentrating on RR-interval irregularity and QRS morphology. Cardiac-Net thus contributes a validated wearable acquisition layer and a rigorously, record-wise cross-validated detection model, together with an honest characterization of the false-alarm and calibration challenges that remain before postoperative clinical deployment.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.