Comparative outcomes of balloon-expandable versus self-expanding transcatheter aortic valves: insights from a large-scale German registry

Aug 2026 · BMC Cardiovascular Disorders · Vol 26 · 0 citations · 27 references
Medicine

TL;DR

In this large, real-world cohort, self-expanding valves were associated with lower in-hospital mortality and major bleeding but a higher risk of stroke and permanent pacemaker implantation compared with balloon-expandable valves.

Abstract

While transcatheter aortic valve replacement (TAVR) has become an established alternative to surgical aortic valve replacement (SAVR), the comparative outcomes of balloon-expandable (BE) and self-expanding (SE) valve technologies remain an area of ongoing investigation. Using the German DESTATIS database, we analyzed 48,565 transfemoral TAVR procedures performed between 2021 and 2022. Outcomes were compared between BE (n = 23,412) and SE (n = 25,153) valves using a double/debiased machine learning estimator to account for potential confounding. Key endpoints included in-hospital mortality, major bleeding, stroke, acute kidney injury, mechanical ventilation > 48 h, postoperative delirium, permanent pacemaker implantation (PPI), length of hospital stay, and reimbursement. Descriptively, SE valves were associated with significantly lower in-hospital mortality (1.6% vs. 2.0%, p < 0.001) and major bleeding (1.4% vs. 2.1%, p < 0.001) but a higher risk of stroke (2.4% vs. 1.9%, p < 0.001). A trend towards higher risk of PPI was observed (p = 0.078). After adjustment, patients with SE valves are at lower risk for in-hospital mortality (RR 0.85, p = 0.049) and major bleeding (RR 0.78, p = 0.006), but had a higher risk of stroke (RR 1.35, p < 0.001) and permanent pacemaker implantation (RR 1.09, p = 0.028). Subgroup analysis indicated that older and high-risk patients, particularly those aged ≥ 85 years, showed a stronger association with lower in-hospital mortality for SE valves, whereas younger patients exhibited a trend favouring BE valves. BE valves were also associated with a modestly higher reimbursement (€209 per case, p = 0.004). In this large, real-world cohort, self-expanding valves were associated with lower in-hospital mortality and major bleeding but a higher risk of stroke and permanent pacemaker implantation compared with balloon-expandable valves. Because prosthesis choice in routine practice is highly individualized and driven by anatomical and procedural factors not captured in administrative data, these associations are hypothesis-generating and cannot support device-selection recommendations.

Read PDF

Similar papers

Sep 2026

Long-term outcomes after balloon- or self-expandable transcatheter aortic valve replacement in small aortic annuli.

The need for further investigations using larger cohorts and contemporary devices to validate long-term comparative outcomes of BEV and SEV in patients with SAA is underscore the need for further investigations using larger cohorts and contemporary devices to validate long-term comparative outcomes.

Toshinobu Ryuzaki, Kentaro Hayashida, Kei Kamata et al. · 0 citations
Oct 2026

Current Generation Self-Expanding and Balloon-Expandable Transcatheter Aortic Valve Replacement: A Retrospective Multicenter Analysis.

BACKGROUND Evolving transcatheter aortic valve replacement (TAVR) technology warrants updated comparisons of the most commonly used current generation self-expanding (SE) versus balloon-expandable (BE) transcatheter heart valves (THV). METHODS This 9-center retrospective analysis stratified patients undergoing TAVR f...

Emily C. Scheffel, Kristin Putman, Lauryn A. Ridley et al. · 0 citations
Aug 2026

Newer-generation balloon-expandable vs. self-expanding transcatheter aortic valves: a propensity score matched analysis.

Among patients treated with newer-generation transcatheter valves, SEV demonstrated more favorable hemodynamic performance compared with BEV, however, short- and mid-term mortality rates remained similar between the two groups.

M. Baudo, S. Sicouri, Dimitrios E. Magouliotis et al. · 1 citation
Open access Aug 2026

Redo-Transcatheter Aortic Valve Replacement With Self-Expanding Valves: A U.S. Registry Analysis.

In a national registry, redo-TAVR with the Evolut platform was associated with low procedural complication rates and clinical outcomes comparable with those observed with native TAVR and support redo-TAVR with Evolut as a feasible and effective treatment strategy in appropriately selected patients.

Toby Rogers, V. Bapat, S. Chetcuti et al. · 1 citation
Review Open access Sep 2026

Balloon-Expandable Versus Self-Expandable Transcatheter Aortic Valve Implantation Devices: A Contemporary Systematic Review

Background/Objectives: Transcatheter aortic valve implantation (TAVI) is an established treatment for severe aortic stenosis. Prosthesis selection is increasingly important because balloon-expandable valves (BEVs) and self-expandable valves (SEVs) differ in deployment, hemodynamics, and lifetime-management implications...

Ioannis Apergis, Georgios P. Georghiou, Panos Georghiou et al. · 0 citations
Oct 2026

Early outcomes of the Octapro balloon-expandable transcatheter heart valve in an unrestricted cohort of patients with aortic valve stenosis: the MyPro registry.

BACKGROUND Data on early outcomes of the novel balloon-expandable (BE) Octapro transcatheter heart valve (THV) in real-world practice are limited. We sought to assess procedural safety and early outcomes of the Octapro in patients with severe native aortic stenosis (AS) undergoing transcatheter aortic valve implantatio...

A. Ielasi, E. Moscarella, Gregor Verček et al. · 0 citations