Skip to content
Open access

Redo-Transcatheter Aortic Valve Replacement With Self-Expanding Valves: A U.S. Registry Analysis.

Aug 2026 · JACC: Cardiovascular Interventions · Vol 19 16, pp. 2204-2216 · 1 citation · 10 references
Medicine

TL;DR

In a national registry, redo-TAVR with the Evolut platform was associated with low procedural complication rates and clinical outcomes comparable with those observed with native TAVR and support redo-TAVR with Evolut as a feasible and effective treatment strategy in appropriately selected patients.

Abstract

Background

Redo-transcatheter aortic valve replacement (TAVR) for failed transcatheter heart valves is expected to increase, but data on outcomes with self-expanding valves remain limited.

Objectives

The aims of this study were to evaluate procedural, clinical, and quality-of-life outcomes following redo-TAVR using self-expanding Evolut valves and to compare these outcomes with those among a contemporary native TAVR cohort.

Methods

Outcomes after redo-TAVR with Evolut R, Evolut PRO, and Evolut PRO+ valves in the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry were analyzed and compared with outcomes after native-valve TAVR using the same valve platform during the same study period. The primary endpoints were all-cause mortality, stroke, and readmission at 30 days and 1 year.

Results

Among 439 redo-TAVR patients (mean age 78.9 ± 9.8 years, 63.1% women), procedural complication rates were low. Redo-TAVR reduced transvalvular gradients at 1 year, although gradients remained modestly higher than after native TAVR (11.3 ± 6.1 mm Hg vs 8.2 ± 4.6 mm Hg; P < 0.001). After adjustment, clinical outcomes were similar between redo-TAVR and native TAVR at 30 days (mortality adjusted HR: 0.66 [95% CI: 0.39-1.13; P = 0.129]; stroke adjusted HR: 0.95 [95% CI: 0.54-1.68; P = 0.853]; readmission adjusted HR: 0.88 [95% CI: 0.65-1.20; P = 0.422]) and 1-year (mortality adjusted HR: 0.91 [95% CI: 0.72-1.15; P = 0.441]; stroke adjusted HR: 0.91 [95% CI: 0.63-1.34; P = 0.644]; readmission adjusted HR: 0.92 [95% CI: 0.76-1.13; P = 0.439]). Improvements in functional status and quality of life were observed early after redo-TAVR and were sustained through 1 year. Findings were consistent across prespecified subgroups.

Conclusions

In a national registry, redo-TAVR with the Evolut platform was associated with low procedural complication rates and clinical outcomes comparable with those observed with native TAVR. These findings support redo-TAVR with Evolut as a feasible and effective treatment strategy in appropriately selected patients.

Read PDF

Similar papers

Review Open access Aug 2026

Redo-Transcatheter Aortic Valve Implantation Versus Surgical Explantation in Patients With Previous Transcatheter Aortic Valve Implantation: A Systematic Review and Meta-Analysis.

BACKGROUND As transcatheter aortic valve implantation (TAVI) expands to younger and lower-risk populations, failed transcatheter heart valves are increasingly encountered, yet the optimal reintervention strategy remains uncertain. This meta-analysis aimed to compare the outcomes of redo-TAVI (TAVI-in-TAVI) versus surgi...

N. Ktenopoulos, A. Apostolos, D. Terentes-Printzios et al. · 1 citation
Open access Sep 2026

Clinical Outcomes and Valve Performance of Intra-Annular Self-Expanding Transcatheter Aortic Valve in Valve-in-Valve Procedures: Insights From the NAViV Registry.

BACKGROUND Most evidence for transcatheter aortic valve replacement (TAVR) for valve-in-valve procedures comes from balloon-expandable and supra-annular self-expanding valves. However, data on intra-annular self-expanding valves remain limited. The objectives of this registry were to evaluate the short- and midterm out...

Jorge F. Chavez, G. Tirado-Conte, Y. Kobari et al. · 0 citations
Open access Aug 2026

Outcomes of Supra-Annular vs Intra-Annular Self-Expanding Valves in Valve-In-Valve Transcatheter Aortic Valve Replacement.

BACKGROUND Self-expanding valves appear to have superior hemodynamics compared with balloon-expandable valves for valve-in-valve transcatheter aortic valve replacement (ViV-TAVR). OBJECTIVES This study aimed to compare echocardiographic and clinical outcome data between supra-annular self-expanding valves (SASEVs) an...

Kuljit Singh, E. Dababneh, M. Matta et al. · 1 citation
Aug 2026

Newer-generation balloon-expandable vs. self-expanding transcatheter aortic valves: a propensity score matched analysis.

Among patients treated with newer-generation transcatheter valves, SEV demonstrated more favorable hemodynamic performance compared with BEV, however, short- and mid-term mortality rates remained similar between the two groups.

M. Baudo, S. Sicouri, Dimitrios E. Magouliotis et al. · 1 citation
Open access Aug 2026

Clinical Outcomes of the Allegra Transcatheter System in Bioprosthetic Aortic Valve Failure: A Multicentre Valve-in-Valve Registry.

INTRODUCTION The prevalence of bioprosthetic aortic valve failure is increasing due to the broader use of bioprosthetic valves, both surgical and transcatheter, and an ageing population. Registry data indicate a higher risk of coronary obstruction and elevated gradients following valve-in-valve transcatheter aortic val...

Hilal Khan, Mohamed Ali, Abdalazeem Ibrahem et al. · 0 citations
Open access Sep 2026

Five-Year Follow-Up of Transcatheter Aortic Valve Replacement With Self-Expanding Intra-Annular Versus Commercially Available Valves.

In patients at high or extreme surgical risk, TAVR with the self-expanding intra-annular transcatheter heart valve had similar 5-year overall survival, stroke rates, and valve function compared with commercially available valves.

Raj R. Makkar, Wen Cheng, Ron Waksman et al. · 0 citations