Skip to content
Open access

Load distribution for screw-retained fixed dental prostheses with different implant-abutment connection: A nonlinear finite element analysis.

Aug 2026 · Journal of Prosthodontic Research · 0 citations · 32 references
Medicine

TL;DR

Assessing the impact of two different implant-restoration connection types on stress distribution at implant components and bone as well as displacement at the implant-abutment-restoration interface found connection design may influence stress, strain, and displacement within the implant-abutment complex and surrounding bone.

Abstract

Purpose

The purpose of this nonlinear finite element analysis study was to assess the impact of two different implant-restoration connection types on stress distribution at implant components and bone as well as displacement at the implant-abutment-restoration interface.

Methods

Two different implant-restoration connection types (indirect and direct) were utilized in the modeling process, and two implant-supported distal 3-unit cantilevered restorations with surrounding bone were designed. Nonlinear friction contact was defined between the implant, abutment, cap, and occlusal screw components for indirect implant-restoration connection and between the implant, abutment, and screw components for direct implant-restoration connection. Vertical and oblique forces were applied separately to the restorations under four different loading conditions. The study assessed both the magnitude and distribution of the Von Mises stresses, as well as the characteristics of displacement.

Results

Oblique load conditions resulted in increased stress and displacement values at the implant-abutment complex. Especially in the direct implant-restoration connection, the stress values in the screws and implants were notably higher. The highest displacement was observed in the screws for the indirect connection and in the abutments for the direct connection.

Conclusions

Connection design may influence stress, strain, and displacement within the implant-abutment complex and surrounding bone. Different types of implant-restoration connections may lead to variations in these biomechanical parameters. Further clinical studies are required to evaluate the clinical relevance of these findings.

Read PDF

Similar papers

Open access Sep 2026

Comparison of fracture resistance between two internal connections implant-abutment designs under compressive loading-An In Vitro study

Context: Longevity and success of dental implants play an important role in oral health of a patient. One of the key factors influences the stability and reliability of dental implants on internal connection of abutment to the implant body. Therefore, this article evaluates the fracture resistance of two implant abutme...

Khushboo Verma, A. Gupta, Mohammad Faisal Khan et al. · 0 citations
Open access Oct 2026

A Comparative Finite Element Study on the Biomechanical Effect of Implant Crown Screw Access Channel Filled by Direct vs. Indirect Restoration Materials

Background: The restorative material used to seal the screw access channel in screw-retained implant-supported crowns may influence the biomechanical behavior and mechanical performance of the restoration. Objective: To evaluate the influence of different screw access channel restorative materials on stress distributio...

A. Al-zahawi, Kale Mohammad, R. Ibrahim et al. · 0 citations
Open access Sep 2026

The effect of implant level in single six-support bridge-like prosthesis designs on the stress-strain state of structural elements based on three-dimensional mathematical modeling

Objective. To evaluate the stress-strain state of bone tissue supported by six dental implants under various types of occlusal loading by finite element analysis. Materials and methods. A three-dimensional finite element model of the mandibular segment with six implants and a fixed bridge prosthesis was developed. The...

S. Serebryanyy, A. Muraev, K. Salekh et al. · 0 citations
Sep 2026

Effect of Implant Diameter, Implant Length, and Prosthesis Splinting on Stress Distribution in Posterior Maxillary Implant-Supported Restorations: A Three-Dimensional Finite Element Analysis

Purpose:To evaluate and compare the influence of implant diameter, implant length, and prosthetic splinting on stress distribution in posterior maxillary implant-supported restorations using three-dimensional finite element analysis.Materials and Methods:Ten three-dimensional finite element models of the posterior maxi...

Ishita Choudhary · 0 citations
Open access Aug 2026

Influence of implant configuration on stress distribution in quad zygoma implant systems: A finite element analysis.

PURPOSE This study aimed to evaluate the effect of different zygomatic implant configurations on the biomechanical behavior of implant-supported prosthetic systems under varying bone conditions using finite element analysis. MATERIALS AND METHODS Four three-dimensional (3D) finite element models were developed based...

Erçin Samunahmetoğlu, Ilgın Arı, Arzum Yilmaz · 0 citations
Open access Sep 2026

Effect of Connection Geometry and Cantilever Length on the Mechanical Behavior of Ti6Al4V and PEEK Bar-Supported Implant Prostheses with Angled Abutments

Angled abutments and cantilever extensions in bar-supported full-arch implant prostheses may generate bending moments and localized stress concentrations within prosthetic components and peri-implant bone. Implant-supported rehabilitation becomes biomechanically more demanding in completely edentulous patients with pos...

Gökçen Akgün · 0 citations