High photovoltaic (PV) penetration can increase active power losses and cause steady-state voltage violations in distribution networks. This paper develops an integrated day-ahead and intraday voltage/var control (VVC) framework that coordinates discrete and continuously controllable devices while explicitly checking the residual of the branch-flow second-order cone relaxation (SOCR). A common 15 min time grid is adopted: on-load tap changer (OLTC) and capacitor-bank (CB) decisions are constrained to remain unchanged within each hourly block, whereas static var compensators (SVCs) and PV inverters are scheduled every 15 min. The day-ahead stage minimizes network losses subject to switching limits and determines the discrete-device schedules. The intraday stage fixes these schedules and uses the normal-boundary intersection (NBI) method to generate trade-off solutions between average voltage deviation and active power loss. A sequential difference-of-convex programming (DCP) correction is activated when the SOCR residual exceeds the prescribed tolerance. For two representative 15 min intervals of the modified balanced single-phase IEEE 123-bus feeder, the maximum residuals of all nine reported Pareto solutions are below 4.805 × 10−5, and the most demanding voltage deviation subproblem converges after 12 DCP iterations. The results demonstrate the feasibility of the proposed deterministic coordination framework; forecast-error robustness, broader method comparisons, and field validation remain subjects for further study.
This paper proposes a deterministic bilevel optimization framework for the coordinated operation of Virtual Power Plants (VPPs) embedded in an active distribution network, which retains the full AC Optimal Power Flow equations, producing a bilevel Mixed-Integer Nonlinear Program (MINLP).
Laura M. Barajas-Arguello, R. A. Núñez-Rodríguez, Daniel Gebbran et al.· 0 citations
Active distribution networks with high penetration of PV, BESS, and EV charging face significant voltage regulation challenges and accelerated OLTC wear. This paper proposes a coordinated multi-layer voltage control framework operating across multiple time scales. It integrates fast local fuzzy Volt–Var and state-of-ch...
Weverson dos Santos Cirino, T. Soares, I. Torné· Revista DCS· 0 citations
Renewable power plants with co-located battery energy storage systems (BESSs) coordinate forecast-deviation control, renewable-surplus management, electricity-price arbitrage, and ancillary-service commitments through the shared power and energy capability of the battery. This study develops a layered framework for sce...
Jing Hu, Yan-Hao Wang, Na-Na Li et al.· Energies· 0 citations
An edge computing-enabled optimal control method is proposed for low-voltage distribution networks organized as distribution transformer clusters (DTCs) that reduces overvoltage occurrences in TQ1 by 81.0% and eliminates undervoltage occurrences under four PV scenarios with SOP-based balancing.
The quality of electricity supply in distribution networks is critically dependent on minimizing active power losses and ensuring voltage stability. This study proposes a unified multi-objective optimization approach for the simultaneous placement and sizing of a photovoltaic (PV) source and a static var compensator (S...
H. Ibrahim, A. Issaka, Moussa Gonda et al.· International Journal of App...· 0 citations
When large-scale wind power bases are connected to weak grids, post-fault transient voltage recovery becomes a critical constraint on stable system operation. This paper proposes a multiobjective sizing framework for a grid-following static var generator (SVG) in which a reduced-order RK4 transient model is embedded di...
Yang Kou, Ji Li, Ying-Li Huo et al.· Electronics· 0 citations