Jul 2026· La radiologia medica· Vol 131, pp. 1535 - 1546· 0 citations· 36 references
Medicine
TL;DR
PCD-CT LIE demonstrated the highest CNR at 40-keV VMI with 2-mm slice thickness, regardless of scar pattern, BMI, or ICD presence, regardless of scar pattern, BMI, or ICD presence.
PURPOSE
To compare the performance of different reconstruction kernels and sharpness levels in photon-counting detector CT (PCD-CT) for post-transarterial chemoembolization (TACE) imaging of hepatocellular carcinoma (HCC), with particular emphasis on residual viable tumor conspicuity, and to identify reconstruction set...
Meng Yuan, Dan-Dan Wang, Zhong-Xing Shi et al.· Abdominal Radiology· 0 citations
Background/Objectives: This study aimed to investigate the impact of low-energy virtual monoenergetic imaging (VMI) on quantitative and qualitative image characteristics, as well as its effect on the diagnostic assessability of thoracic arteries in photon-counting computed tomography angiography (CTA). Methods: We retr...
Andreea I. Nica, C. Booz, G. Bucolo et al.· Diagnostics· 0 citations
While UHR acquisition provides highest image quality in PCD-CT cCTA, lower-dose acquisition modes achieve comparable diagnostic accuracy for coronary stenosis detection and Protocol selection should therefore be individualized, and prospective controlled studies are required.
Thomas Stein, Friederike Lang, F. Bamberg et al.· Zeitschrift für Medizinische...· 0 citations
To determine the best combination of reconstruction parameters on a spectral photon-counting CT (SPCCT) system to improve detection of peritoneal metastases (PMs) on virtual monoenergetic images (VMIs) at 40 keV. A spectral phantom was scanned using SPCCT and dual-energy CT (EID-DECT) at 8.5 mGy (CTDIvol). 40 keV VMIs...
J. Greffier, R. Grange, D. Dabli et al.· European Radiology Experimen...· 0 citations
To investigate the clinical application value of multi-parameter imaging with dual-layer detector spectral CT (DLCT) for GTH visualization. A total of 61 patients who underwent abdominal portal venous phase-enhanced SLCT were retrospectively enrolled. The raw image data were reconstructed into 120 kVp conventional imag...
Xiao-Ou He, Nai-Wen Mu, Jia-Cun Li et al.· Discover Imaging· 0 citations
Color K-edge imaging is feasible with multiple high-Z elements, whilst outperforming the performance of conventional imaging, paving the way for lung SPCCT functional imaging.
Agnieszka Gutwinska, Derick Rosario, A. Robert et al.· Physica medica (Testo stampa...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.