Radiation Dose Optimization in Coronary CT Angiography: A Quality Improvement Initiative.

Sep 2026 · JACC Case Reports · Vol 31 37, pp. 109329 · 0 citations · 11 references
Medicine

TL;DR

Technologist-driven protocol optimization can substantially reduce CCTA radiation exposure without compromising image quality and may serve as a scalable model for cardiovascular imaging programs in resource-constrained settings.

Abstract

Background

Coronary computed tomography angiography (CCTA) is increasingly used for the evaluation of coronary artery disease; however, radiation exposure remains a patient safety concern. Data on radiation dose optimization from low- and middle-income countries are limited. PROJECT

Rationale

Tabba Heart Institute Karachi identified opportunities to reduce CCTA radiation exposure through implementation of heart rate and body mass index-guided acquisition protocols while maintaining image quality. PROJECT SUMMARY A quality improvement initiative was implemented using patient-specific scanning protocols. A total of 422 CCTA examinations were evaluated, including 117 preintervention and 305 postintervention studies. Median effective radiation dose decreased by 45.5%, from 8.8 mSv to 4.8 mSv (P < 0.001). CCTA dose-length product decreased by 46.5% and total dose-length product by 39.8% (both P < 0.001). No significant differences were observed in image quality metrics or repeat scan rates. TAKE-HOME MESSAGE Technologist-driven protocol optimization can substantially reduce CCTA radiation exposure without compromising image quality and may serve as a scalable model for cardiovascular imaging programs in resource-constrained settings.

Read PDF

Similar papers

Open access Oct 2026

Reduced contrast volume in coronary CT angiography: effects on coronary attenuation

A multivariable linear model examined coronary attenuation as a function of protocol epoch, kVp, body weight, heart rate, and iodine delivery rate and found that protocol epoch remained independently associated with lower attenuation after adjustment for kVp, weight, heart rate, and iodine delivery rate.

Perihan Adel Ali El Naqeeb, M. Shafaa, A. M. Ibrahim et al. · 0 citations
Open access Oct 2026

Optimization of pediatric computed tomography protocols: dose reduction without loss of image quality

This study aimed to optimize pediatric computed tomography (CT) protocols for abdomen and chest examinations, focusing on reducing radiation dose without compromising diagnostic image quality. Information was collected from factory protocols, current-modulated protocols, and those used in the routine of a university ho...

Maria Rosane Neczypor, Carla Roberta de Barros Dias, J. V. Real et al. · 0 citations
Review Open access Oct 2026

Development of diagnostic reference levels and acceptable quality dose for computed tomography in an Indian tertiary care center

Background Computed tomography (CT) contributes substantially to medical radiation exposure, making diagnostic reference levels (DRLs) important for dose optimization. This study aimed to establish preliminary institutional DRLs and evaluate acceptable quality dose (AQD) at an Indian tertiary care center. Methods A cro...

Ashutosh Pandey, V. K. Dhingra, Pankaj Sharma · 0 citations
Oct 2026

Intraindividual Comparison of Radiation Dose and Image Quality: Photon-counting versus Energy-integrating Detector CT in Obesity.

Background Maintaining diagnostic CT image quality in patients with obesity remains challenging because increased x-ray attenuation is often offset by higher radiation exposure. Photon-counting CT (PCCT) has demonstrated improved dose efficiency and image quality, but intraindividual data in this population are limited...

Jan Hegmanns, S. Zensen, D. Rosok et al. · 1 citation
Open access Oct 2026

Impact of Photon-Counting CT Acquisition Modes on Coronary Stenosis Assessment and Radiation Dose: A Phantom and Clinical Evaluation.

While UHR acquisition provides highest image quality in PCD-CT cCTA, lower-dose acquisition modes achieve comparable diagnostic accuracy for coronary stenosis detection and Protocol selection should therefore be individualized, and prospective controlled studies are required.

Thomas Stein, Friederike Lang, F. Bamberg et al. · 0 citations
Review Sep 2026

Assessment of CT doses and practices based on large data collected over four years in six hospitals of regional health network.

INTRODUCTION Computed tomography (CT) contributes substantially to medical radiation exposure, and considerable dose variation has been reported across scanners and facilities. This study evaluated CT radiation doses and practices across eight CT scanners in six facilities within a regional healthcare network in Canada...

M. Nassiri, N. Moghadam, Ariane-Sophie Painchaud-Bouchard et al. · 1 citation