Skip to content
Open access

Automated assessment of echocardiograms to aid diagnosis of heart failure with preserved ejection fraction

Sep 2026 · European Heart Journal - Digital Health · Vol 7 · 1 citation · 21 references
Medicine

TL;DR

The HFA-PEFF and H2FPEF scores based on automated and manual echocardiographic analysis showed similar diagnostic accuracy, suggesting automated HFpEF diagnosis using deep learning analysis of echocardiograms is feasible.

Abstract

Abstract Aims Diagnosis of heart failure with preserved ejection fraction (HFpEF) using the HFA-PEFF and H2FPEF scores remains challenging in clinical practice and relies on echocardiographic assessment. We aimed to determine whether diagnostic scoring based on automated deep learning interpretation of echocardiograms performs similar to manual measurements in diagnosing HFpEF. Methods and results We analysed echocardiograms using an automated deep learning algorithm and manually in three cohorts: a test cohort (102 HFpEF patients diagnosed by right heart catheterization and echocardiography), an ambulatory validation cohort (129 HFpEF patients), and a diagnostic validation cohort (n = 427, of which 182 HFpEF and 245 non-HFpEF patients). We evaluated correlations between automated and manual HFA-PEFF and H2FPEF scores across cohorts, their correlation with pulmonary capillary wedge pressures (PCWP), and compared diagnostic accuracy using the area under the curve (AUC). Automated and manual measurements showed good agreement across cohorts, with good correlations between HFA-PEFF (0.78–0.86) and H2FPEF (0.96–0.98) scores and similar correlations with PCWP. One in five patients with high-likelihood HFpEF based on manual HFA-PEFF scores was classified as intermediate-likelihood by automated scores due to lower estimated left atrial volumes, without consistent interaction with atrial fibrillation. Areas under the curve for automated HFA-PEFF and H2FPEF scores did not consistently differ from manual scores {0.70 [95% confidence interval (CI): 0.66–0.74] vs. 0.71 [95% CI: 0.66–0.75] and 0.78 [95% CI: 0.73–0.82] vs. 0.75 [95% CI: 0.71–0.80], respectively}. Conclusion The HFA-PEFF and H2FPEF scores based on automated and manual echocardiographic analysis showed similar diagnostic accuracy, suggesting automated HFpEF diagnosis using deep learning analysis of echocardiograms is feasible.

Read PDF

Similar papers

Sep 2026

Exercise stress echocardiography for diagnosis of heart failure with preserved ejection fraction: a multicentre study.

Addition of LA strain imaging with optimized rule-in or rule-out values improves diagnostic triage by expanding non-invasive rule-in/rule-out classifications while identifying patients who still require invasive testing in the evaluation of HFpEF.

T. Harada, Yogesh N. V. Reddy, H. Sorimachi et al. · 2 citations
Case report Open access Sep 2026

HFpEF Diagnosis Using Integrated H2FPEF Scoring in Echocardiogram Reports.

BACKGROUND Heart failure with preserved ejection fraction (HFpEF) accounts for a substantial and growing proportion of heart failure hospitalizations, yet diagnosis remains challenging due to the need for integrated clinical and echocardiographic assessment rather than a single definitive parameter. PROJECT RATIONALE...

Cesar A. Rivera-Tovar, Deepika Vunnam, Abdelhameed Nienaa et al. · 0 citations
Open access Aug 2026

Diagnostic Accuracy of the H2FPEF Score for Identifying Heart Failure with Preserved Ejection Fraction in Adults with Suspected HFpEF at a Tertiary Care Hospital in Pakistan

The H2FPEF score demonstrated good diagnostic accuracy for identifying HFpEF among adults with suspected disease in this tertiary-care cohort; however, because the study population represented a selected high-prevalence referral cohort, external validation in broader clinical settings is warranted.

Malik Faisal Iftekhar, Muhammad Adil, Uzma Siddique · 0 citations
Open access Sep 2026

Point-of-care echocardiography screening for hypertrophic cardiomyopathy using automated deep-learning analysis

Abstract Aims Hypertrophic cardiomyopathy (HCM) remains underdiagnosed due to limited access to expert imaging. We developed and validated a deep-learning (DL)-based echocardiographic model adaptable to point-of-care ultrasound (POCUS) for scalable HCM screening. Methods and results We retrospectively analysed 134 956...

N. Karra, Y. Klempfner, V. Copeland et al. · 0 citations
Open access Sep 2026

Comparing the Prognostic Performance Using Various Diagnostic Scoring Systems in Heart Failure With Preserved Ejection Fraction: Insights From the Nationwide Prospective Registry.

Diagnostic scores for HFpEF can provide prognostic value and the proposed simple echocardiography and natriuretic peptide-based scoring systems offered superior risk discrimination.

Hung-Yu Chang, Wen-Hung Huang, Kuo-Tzu Sung et al. · 0 citations
Open access 2025

Comparing Left Atrial Strain and the HFA-PEFF Score in Diagnosing Heart Failure with Preserved Ejection Fraction: A Cross-Sectional Study

Highlights The LA strain demonstrates diagnostic efficacy comparable to the HFA-PEFF score in diagnosing HFpEF. Integrating LA strain indices into current guidelines could enhance future HFpEF diagnostics. Background: Heart failure with preserved ejection fraction (HFpEF) has a high hospitalization rate. While recent g...

Hai Nguyen Ngoc Dang, Thang Viet Luong, B. Ho et al. · 1 citation

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.