Aug 2026· International Conference on Medical Image Computing and Computer-Assisted Intervention· Vol abs/2608.23347· 1 citation· 31 references
Computer Science
TL;DR
This work proposes BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift, and introduces a Signal Quality Index-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates.
Abstract
Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time. However, existing TTA methods often underperform on ECG tasks, since naive online updates ignore the hierarchical beat-rhythm structure of cardiac cycles and are vulnerable to signal artifacts, which leads to unstable adaptation and model drift. We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift. First, to handle pervasive ECG artifacts, we introduce a Signal Quality Index (SQI)-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates. Second, to leverage ECG's beat-rhythm semantics, we enforce dual-level consistency so the model preserves beat morphology and rhythm dynamics while adapting to shifted acquisition conditions. Extensive experiments on multi-label ECG diagnosis across three adaptation protocols, using PTB-XL as the source domain and CPSC2018/Georgia as two target domains, demonstrate the effectiveness of our method, yielding an average +2.70% relative improvement in Macro-F1 over the best competing method.
BeatFlow-ECG is presented, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements and achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics.
Mohamed S. Kamel, Sahar Selim, Walaa Medhat et al.· 0 citations
Long-duration ECG monitoring is increasingly used to detect intermittent and subtle cardiac abnormalities, yet real-world recordings are frequently contaminated by non-stationary artifacts (baseline wander, motion, muscle activity) that impair interpretability and can degrade automated diagnosis—particularly as r...
S. Ruipérez-Campillo, B. Morel, A. Streicht et al.· European Heart Journal· 0 citations
Electrocardiography (ECG) is central to cardiac monitoring because it captures rhythm, beat timing, and clinically meaningful waveform morphology. In practical acquisition settings, ECG recordings are often corrupted by baseline drift, muscle activity, electrode motion, and powerline interference, which can obscure loc...
Mohamed S. Kamel, Sahar Selim, Walaa Medhat et al.· International Conference on...· 0 citations
Electrocardiogram (ECG) signals are essential for arrhythmia diagnosis. With the growing adoption of long-term monitoring via wearable and portable devices, energy-efficient acquisition has become critical, motivating the development of ECG super-resolution (SR) techniques to reconstruct high-resolution signals from lo...
Fan-Yi Hsu, I. Chiu, Kuan-Chen Wang et al.· 0 citations