A phase-aligned temporal reparameterization that maps normalized within-interval time to a latent motion phase according to deformation variation intensity, thereby better modeling non-uniform motion progression and achieving state-of-the-art performance over existing baselines.
Abstract
4D medical image interpolation aims to recover missing volumes from sparsely observed time points and is important for dynamic anatomical analysis in applications such as cardiac MRI and thoracic CT, where motion is often repetitive or near-periodic over clinically relevant intervals. A key challenge is that this structure is not always encoded directly in deformation representations for interpolation. In addition, physiological motion is often non-uniform, so equal temporal intervals do not necessarily correspond to equal amounts of anatomical change. To address these issues, we formulate interpolation as learning a continuous deformation process with a phase-structured prior. Given two endpoint volumes, we parameterize a phase-conditioned velocity field with a finite Fourier basis, which embeds near-periodic motion patterns directly into the deformation space and supports continuous querying at arbitrary target times. We further introduce a phase-aligned temporal reparameterization that maps normalized within-interval time to a latent motion phase according to deformation variation intensity, thereby better modeling non-uniform motion progression. Intermediate volumes are then synthesized by continuously warping both endpoints, followed by bidirectional fusion and lightweight residual refinement. Experiments on ACDC and 4D-Lung show that the proposed method achieves state-of-the-art performance over existing baselines while producing anatomically plausible and coherent intermediate volumes from sparse observations.
This work proposes low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppres...
Hao-Jin Li, Hengzhuo Wang, Chang Liu et al.· 0 citations
This work proposes a framework to directly learn the continuous-time solution of a non-autonomous ODE formulated as a two-parameterflow map by enforcing cocycle consistency, a fundamental structural property of time-varying flows, by enforcing cocycle consistency during training.
Coronary Mask Guided Registration (CMGR) provides an effective approach for constructing continuous-time 4D cardiac CT datasets and can be used in system design simulations and in reconstruction algorithm development, thereby facilitating advances in cardiac CT imaging.
Yuang Wang, Shuo Wang, Chang-Yu Chen et al.· 0 citations
Medical image segmentation remains challenging in terms of accurate boundary localization and complex-structure preservation, as target regions often exhibit weak boundaries, fine-grained structures, and irregular shapes, while high-quality images and precise annotations are usually limited. Existing generative segment...
Yu-Xin Ai, Zhi-Chang Guo, Fang-Hui Song et al.· 0 citations
Motion-corrupted inverse problems remain a central bottleneck in magnetic resonance imaging (MRI), especially for high-resolution 3D acquisitions where long readouts couple rigid-body displacement with non-Cartesian k-space sampling. We present a physics-informed implicit neural representation (INR) that recasts 3D mot...
Hao-Yuan Le, Qing Wu, Bo-Wen Li et al.· Medical Image Analysis· 0 citations
Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated fr...
Yu-Hao Wang, Zhen-Dong Zhang, E. R. Criscuolo et al.· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.