Skip to content
Preprint

Low-Rank Velocity Fields as a Structural Prior for Unsupervised 4D Medical Image Interpolation

Aug 2026 · 0 citations · 25 references
Computer Science

TL;DR

This work proposes low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppressing voxel-wise high-frequency artifacts.

Abstract

Endpoint-only unsupervised 4D medical image interpolation synthesizes intermediate volumes from sparsely sampled sequences with only the start and end volumes available for training; however, this weakly constrained setting often yields intermediates with unstable boundaries and non-physiological motion, limiting interpretability and downstream analysis. We propose low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppressing voxel-wise high-frequency artifacts. To capture global coordination and local non-rigid details, we model motion in a coarse-to-fine multi-scale scheme and compose scale-wise deformations at inference to synthesize volumes at arbitrary times. We further provide a theoretical analysis showing that, under Tucker parameterization, low-rank parameters control the smoothness energy of the velocity field, explaining why low-rank modeling promotes smoother motion. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance, remaining competitive with methods trained with intermediate-frame supervision, and producing intermediates with improved structural coherence and more stable anatomical contours.

View source

Similar papers

Preprint Aug 2026

Phase-Aligned Finite-Fourier Periodic Deformation for 4D Medical Image Interpolation

A phase-aligned temporal reparameterization that maps normalized within-interval time to a latent motion phase according to deformation variation intensity, thereby better modeling non-uniform motion progression and achieving state-of-the-art performance over existing baselines.

Hao-Jin Li, Hengzhuo Wang, Zhiheng Ma et al. · 0 citations
Open access Sep 2026

Unsupervised high-resolution 3D MRI motion correction via physics-informed implicit neural representations.

Motion-corrupted inverse problems remain a central bottleneck in magnetic resonance imaging (MRI), especially for high-resolution 3D acquisitions where long readouts couple rigid-body displacement with non-Cartesian k-space sampling. We present a physics-informed implicit neural representation (INR) that recasts 3D mot...

Hao-Yuan Le, Qing Wu, Bo-Wen Li et al. · 0 citations
Conference Open access Sep 2026

GeoSFLoRA: Geometry-Conditioned Spectral Flow Low-Rank Adaptation for 2D-to-3D Transfer in Medical Image Segmentation

GeoSFLoRA consistently improves Dice and HD95 on BraTS20, MSD-Prostate, and MSD-Lung, approaching full fine-tuning performance and demonstrating an effective paradigm for 2D-to-3D medical image segmentation.

Qin Hao, Bo-Nian Chen, Shengwei Tian et al. · 0 citations
Preprint Sep 2026

Latent Space Is Not Flat: Rethinking Latent Structure for 3D Medical Image Synthesis

Latent generative models make 3D medical image synthesis computationally practical by generating in a compressed space. However, we show that the common flat Euclidean assumption induced by $\ell_2$ objectives is imprecise: latent-space geometry is so strongly anisotropic that equal-magnitude errors can produce drastic...

Hao-Wen Xue, Hao Chen, He-Xuan Hu et al. · 0 citations
Sep 2026

SSAD: Prior-driven self-supervised staircase artifact denoising via diffeomorphic flow for volumetric medical image surface reconstruction.

SSAD is proposed, a prior-driven self-supervised framework which redefines reconstruction as learning a diffeomorphic flow from boundary voxels to the coherent optimal surface, and demonstrates a super-resolution capability, with the accuracy of its reconstructed surfaces comparable to that achieved by voxel data at 2-...

Jing Shi, Zhan-Hua Zhang, Yuan Xing et al. · 0 citations
Preprint Sep 2026

GR-FM: Geometrically Regularized Flow Matching for SDF-Based Medical Image Segmentation

Medical image segmentation remains challenging in terms of accurate boundary localization and complex-structure preservation, as target regions often exhibit weak boundaries, fine-grained structures, and irregular shapes, while high-quality images and precise annotations are usually limited. Existing generative segment...

Yu-Xin Ai, Zhi-Chang Guo, Fang-Hui Song et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.