This work proposes low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppressing voxel-wise high-frequency artifacts.
Abstract
Endpoint-only unsupervised 4D medical image interpolation synthesizes intermediate volumes from sparsely sampled sequences with only the start and end volumes available for training; however, this weakly constrained setting often yields intermediates with unstable boundaries and non-physiological motion, limiting interpretability and downstream analysis. We propose low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppressing voxel-wise high-frequency artifacts. To capture global coordination and local non-rigid details, we model motion in a coarse-to-fine multi-scale scheme and compose scale-wise deformations at inference to synthesize volumes at arbitrary times. We further provide a theoretical analysis showing that, under Tucker parameterization, low-rank parameters control the smoothness energy of the velocity field, explaining why low-rank modeling promotes smoother motion. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance, remaining competitive with methods trained with intermediate-frame supervision, and producing intermediates with improved structural coherence and more stable anatomical contours.
A phase-aligned temporal reparameterization that maps normalized within-interval time to a latent motion phase according to deformation variation intensity, thereby better modeling non-uniform motion progression and achieving state-of-the-art performance over existing baselines.
Hao-Jin Li, Hengzhuo Wang, Zhiheng Ma et al.· 0 citations
Motion-corrupted inverse problems remain a central bottleneck in magnetic resonance imaging (MRI), especially for high-resolution 3D acquisitions where long readouts couple rigid-body displacement with non-Cartesian k-space sampling. We present a physics-informed implicit neural representation (INR) that recasts 3D mot...
Hao-Yuan Le, Qing Wu, Bo-Wen Li et al.· Medical Image Analysis· 0 citations
GeoSFLoRA consistently improves Dice and HD95 on BraTS20, MSD-Prostate, and MSD-Lung, approaching full fine-tuning performance and demonstrating an effective paradigm for 2D-to-3D medical image segmentation.
Qin Hao, Bo-Nian Chen, Shengwei Tian et al.· Proceedings of the Thirty-Fi...· 0 citations
Latent generative models make 3D medical image synthesis computationally practical by generating in a compressed space. However, we show that the common flat Euclidean assumption induced by $\ell_2$ objectives is imprecise: latent-space geometry is so strongly anisotropic that equal-magnitude errors can produce drastic...
Hao-Wen Xue, Hao Chen, He-Xuan Hu et al.· 0 citations
SSAD is proposed, a prior-driven self-supervised framework which redefines reconstruction as learning a diffeomorphic flow from boundary voxels to the coherent optimal surface, and demonstrates a super-resolution capability, with the accuracy of its reconstructed surfaces comparable to that achieved by voxel data at 2-...
Jing Shi, Zhan-Hua Zhang, Yuan Xing et al.· Medical Image Analysis· 0 citations
Medical image segmentation remains challenging in terms of accurate boundary localization and complex-structure preservation, as target regions often exhibit weak boundaries, fine-grained structures, and irregular shapes, while high-quality images and precise annotations are usually limited. Existing generative segment...
Yu-Xin Ai, Zhi-Chang Guo, Fang-Hui Song et al.· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.