Sep 2026· 2026 IEEE 1st International Conference on Artificial Intelligence Implementation & Applications (ICAIIA)· pp. 280-285· 0 citations· 18 references
Abstract
Breast ultrasound lesion segmentation is a core technical step that supports computer-aided diagnosis of breast diseases and accurate lesion measurement. However, existing segmentation models trained on single-source datasets often suffer from inter-domain distribution shift caused by differences in scanning equipment and scanning protocols across medical institutions, as well as the inherent appearance heterogeneity of lesions. This shift ultimately leads to significant performance degradation. To address this issue, this paper proposes Uncertainty-Calibrated Test-Time Adaptation (UC-TTA), a test-time adaptation framework for cross-dataset breast ultrasound segmentation. The source model is trained on the labeled public BUSI dataset, and only uses the validation set of this dataset to complete calibration. This study conducted verification on three public external datasets: BUS-UCLM, BrEaST-Lesions-USG, and BUS-BRA. The fixed-threshold UC-TTA reduced the expected calibration error from 0.088 to 0.070 on BUS-UCLM, but was accompanied by a small drop in the Dice coefficient, which fell from 0.186 to 0.176. The protected UC-TTA, which integrates threshold calibration on the source domain validation set, achieved a Dice coefficient of 0.389 on this dataset, while reducing the false positive rate for normal images from 0.603 to 0.401. Experiments on ResNet34-U-Net pre-trained on three subsets showed that the source domain calibrated threshold method reached a Dice coefficient of 0.729 on BUS-UCLM, while the protected UC-TTA reached 0.726. The calibrated UC-TTA also increased the Dice coefficient of Attention U-Net from 0.497 to 0.593 on BrEaST-Lesions-USG.
A targeted source-inclusion sensitivity analysis indicates model- and cohort-dependent sensitivity to training-pool composition, rather than a universal benefit from adding data or a universally preferred configuration, in breast ultrasound segmentation.
Lin Ma· Medical Engineering and Phys...· 0 citations
Accurate segmentation of breast lesions in ultrasound remains challenging due to limited data and acquisition variability.
To quantify how common augmentation operators and their combinations affect cross-dataset generalization of a standard U-Net for breast lesion segmentation.
We trained on the...
V. Rahmawati, Syahril Siregar· Imaging· 0 citations
The findings highlight the importance of external validation, detection-aware evaluation, and efficient deployment for reliable breast ultrasound segmentation.
Rakib Ahammed Diptho, Pial Ghosh, Safiul Haque Chowdhury et al.· Networked Digital Technologi...· 0 citations
The proposed framework substantially outperforms finetuned radiology foundation models and prior methods, improving mean AUROC by nearly 8 points and balanced accuracy by 4 points over the strongest baseline, further demonstrating its effectiveness for robust breast cancer classification.
Benjamin Hamm, Y. Kirchhoff, M. Rokuss et al.· International Conference on...· 1 citation
Tuberculosis remains a major global health burden, creating a need for accurate and generalizable computer-aided screening methods based on chest radiographs. Deep learning models trained on a single imaging cohort can experience substantial performance degradation when applied to data acquired from different instituti...
Aswini Kilaru· Journal of Intelligent Decis...· 0 citations
This study conducted a systematic comparison of three evaluation protocols on the CBIS-DDSM benchmark using EfficientNetB3 under strictly identical architecture, hyperparameters, and augmentation strategies, establishing a methodologically valid benchmark for mammographic mass classification on CBIS-DDSM.