Skip to content
Open access

Peri-implant strain analysis: An in vitro comparison between screw- and cement-retained posterior base metal restorations.

Aug 2026 · Dental and Medical Problems · Vol 63 4, pp. 993-1002 · 0 citations
Medicine

TL;DR

Retention modality appears to influence peri-implant strain development in mesiodistal and occlusogingival dimensions for 3-unit single crown and splinted crown designs.

Abstract

Background

Research is required to characterize peri-implant strain distribution associated with different restorative designs.

Objectives

This in vitro qualitative photoelastic stress analysis aimed to compare the influence of retention modality (screw-retained or cement-retained) on strain development around implants supporting different 3-unit posterior restorative designs. MATERIAL AND

Methods

Six prosthetic restorative designs were evaluated according to retention modality and prosthetic configuration: 3 single crowns, cement-retained and screw-retained (SC-c and SC-s, respectively); 3 splinted crowns (SP-c and SP-s); and simple 3-unit bridges (SB-c and SB-s). All prosthetic units were morphologically identical. A photoelastic resin block incorporating 3 implants was mounted on a loading device that applied vertical loads of 200 N simultaneously at 3 identical loading points on each restoration to simulate chewing, occlusal clenching and deglutition. Fringe lines were photographically recorded and qualitatively analyzed after placement of the restorations and during loading.

Results

Screw-retained restoration with splinted crowns (SP-s) was the only design to exhibit strain in the unloaded state following placement, representing preload strain. Loading-induced strains were observed in SC-c and SC-s, with lower strain levels for SC-c than for SC-s, and in SP-c and SP-s, with lower strain levels for SP-c than for SP-s. Both configurations also exhibited crestal strains. The simple bridge (SB) designs revealed purely axial strains, with no crestal strains, regardless of retention modality.

Conclusions

Retention modality appears to influence peri-implant strain development in mesiodistal and occlusogingival dimensions for 3-unit single crown and splinted crown designs. Screw-retained 3-unit splinted prostheses may generate preload strains around the unloaded implant supporting the restoration. Simple 3-unit bridge designs demonstrated the most favorable strain pattern, regardless of the retention modality.

Read PDF

Similar papers

Open access Sep 2026

Impact of restoration design and material on the mechanical behavior of implant-supported monolithic CAD-CAM single crowns: An in vitro study.

PURPOSE To evaluate the effects of crown design and restorative material on screw loosening and load-bearing performance of monolithic single-implant restorations after cyclic loading. METHODS Sixty implant-supported molar crowns were assigned to a conventional crown design (CCD; n=30), with a centrally positioned im...

Shaza Bishti, Rodi Bingöl, S. Wolfart et al. · 0 citations
Sep 2026

Fracture load of interim 3-unit fixed dental prostheses fabricated using contemporary CAD-CAM polymers: An in vitro study.

STATEMENT OF PROBLEM Although several studies have evaluated the mechanical properties of contemporary computer-aided design and computer-aided manufacturing (CAD-CAM) polymers for interim tooth-supported restorations, research describing mechanical testing under clinically representative conditions is limited. PURPO...

C. A. Jurado, Francisco X. Azpiazu-Flores, M. Antal et al. · 0 citations
Open access Oct 2026

A Comparative Finite Element Study on the Biomechanical Effect of Implant Crown Screw Access Channel Filled by Direct vs. Indirect Restoration Materials

Background: The restorative material used to seal the screw access channel in screw-retained implant-supported crowns may influence the biomechanical behavior and mechanical performance of the restoration. Objective: To evaluate the influence of different screw access channel restorative materials on stress distributio...

A. Al-zahawi, Kale Mohammad, R. Ibrahim et al. · 0 citations
Open access Aug 2026

Clinical performance of a conometric retention system for single implant restorations: 1-year analysis of a prospective multicenter study

The investigated conometric retention system demonstrated high implant and prosthetic survival rates and limited marginal bone changes, however, a clinically relevant incidence of technical complications, including irreversible loss of conometric retention, was observed during the first year of function.

Peter Gehrke, Octavio Weinhold, Pelayo Antuna et al. · 0 citations
Open access Aug 2026

Load distribution for screw-retained fixed dental prostheses with different implant-abutment connection: A nonlinear finite element analysis.

Assessing the impact of two different implant-restoration connection types on stress distribution at implant components and bone as well as displacement at the implant-abutment-restoration interface found connection design may influence stress, strain, and displacement within the implant-abutment complex and surroundin...

Diler Deniz, Nigar Baghirova, Kıvanç Akça · 0 citations
Open access Oct 2026

In vitro comparison of resin cement bond strength to milled and 3D-printed resins.

OBJECTIVE Contemporary minimally invasive strategies for fixed rehabilitation emphasize tooth structure preservation, with secure adhesion between thin restorations and resin cement vital to avoid failure. This study compares bond strengths of a common resin cement to 4 modern milling and 3D-printing resin-based restor...

Jason Tupper, D. Tantbirojn, Wainscott Hollis et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.