Skip to content

Development and Validation of a Reversed-Phase HPLC Method for Estimation of Glimepiride in Rabbit Serum and Its Application to Pharmacokinetic Studies

Sep 2026 · Middle East Research Journal of Pharmaceutical Sciences · 0 citations

TL;DR

The validated RP-HPLC method is simple, sensitive, precise, and accurate, requires only 200 μL of serum, and is suitable for pharmacokinetic, bioavailability, and drug-interaction studies of glimepiride in rabbits.

Abstract

A reversed-phase high-performance liquid chromatography (RP-HPLC) method reported for glimepiride was modified and standardized for its estimation in rabbit serum, using pioglitazone as an internal standard (IS), to support pharmacokinetic evaluation of the drug in a rabbit model. Chromatographic separation was achieved on an RP C18 column (250 × 4.6 mm, 5 μm) using acetonitrile and phosphate buffer (pH 4.3) in a 75:25 (v/v) ratio as the mobile phase at a flow rate of 1 mL/min, with UV detection at 258 nm. Glimepiride and the internal standard were extracted from rabbit serum by liquid–liquid extraction with dichloromethane, and the ratio of the peak area (AUC) of glimepiride to that of pioglitazone was used for quantification. The method was validated for linearity, system suitability, precision, and recovery/accuracy. The calibration curve was linear over 20–1000 ng/mL (y = 0.0089x − 0.0078, r² = 0.9980). The limit of detection (LOD) and limit of quantification (LOQ) were 18.55 and 20.00 ng/mL, respectively. The column gave 14,352 theoretical plates and a tailing factor of 1.08 for glimepiride, with retention times of 6.8–8.02 min for glimepiride and 4.2–5.05 min for the internal standard. Intra-day and inter-day precision (%RSD) were below 3% at all concentrations tested, and absolute recovery ranged from 98.85% to 99.82%. The validated RP-HPLC method is simple, sensitive, precise, and accurate, requires only 200 μL of serum, and is suitable for pharmacokinetic, bioavailability, and drug-interaction studies of glimepiride in rabbits.

View source

Similar papers

Open access Aug 2026

DEVELOPMENT AND VALIDATION OF AN RP-HPLC BIOANALYTICAL METHOD FOR QUANTIFICATION OF RIZATRIPTAN BENZOATE IN RAT PLASMA AND BRAIN HOMOGENATE: APPLICATION TO PHARMACOKINETIC AND BRAIN-TARGETING STUDIES

The developed RP-HPLC method is simple, reproducible, accurate and appropriate for bioanalytical routine quantification of Rizatriptan Benzoate in biological matrices.

Priyanka Das, Bipul Nath, Payal Dasgupta et al. · 0 citations
Open access Sep 2026

Development and validation of a bioanalytical hplc-dad method for ketoprofen quantification in rat plasma and brain tissue: application to pharmacokinetic studies and tissue distribution analysis

This study developed and validated a sensitive high-performance liquid chromatography with diode-array detection method for quantifying Ketoprofen in rat plasma and brain tissue, supporting its application in preclinical pharmacokinetic and tissue-distribution research on KTP.

Camila Oliveira Pacheco, Jamily Rosa Langendorf, Joane Guterres Ferreira et al. · 0 citations
Oct 2026

Validation of Reversed Phase Liquid Chromatographic Method for the Simultaneous Estimation of Irbesartan and Hydrochlorothiazide in their Pharmaceutical Preparations

Background: The present study was aimed to develop and validate a maintenance of robust, accurate and reproducible isocratic reverse-phase high-performance liquid chromatography (RP-HPLC) method that permits the simultaneous quantitation of irbesartan (IRB) and hydrochlorothiazide (HCT) in composite tenders dosage form...

Rana M. Jabbar, A. Saeed · 0 citations
Open access Aug 2026

Reverse - Phase High - Performance Liquid Chromatographic Method Development and Validation for the Estimation of Eletriptan Hydrobromide in Tablet Formulations

The developed RP - HPLC method was effectively utilized for the quantification of Eletriptan Hydrobromide in the marketed formulations of tablets and can be used for quality control analysis due to the simplicity, sensitivity, precision, and reproducibility of the method.

{"name":"Usha Sree G","email":"ushapharma9@gmail.com","affiliati, {"name":"Kondreddy Vinod Kumar","email":"ushapharma9@gmail.com","affi · 0 citations
Open access Sep 2026

A Stability-Indicating RP-HPLC Approach for the Simultaneous Determination of Linagliptin and Dapagliflozin in Bulk and Marketed Formulation

A simple, rapid, accurate, precise, and stability-indicating reversed-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the simultaneous determination of linagliptin (LNG) and dapagliflozin (DPM) in bulk drug and tablet dosage forms. Chromatographic separation was accomplish...

M. Mahale, Ramanlal N. Kachave, Machhindra J. Chavan · 0 citations
Open access Sep 2026

AI-Assisted Stability-Indicating RP - HPLC Method Development and Validation for the Quantitative Estimation of Tafamidis in Bulk Drug and Pharmaceutical Dosage Forms

A stability-indicating reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the quantitative estimation of Tafamidis in bulk drug and pharmaceutical dosage forms. Chromatographic separation was achieved using a Phenomenex Gemini ODS C18 column (250 × 4.6 mm, 5 µm) with...

Badikela Rama Krishna, Challamalla Pavani, B. Vasudeva et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.